Skip to main content
Schneider Electric VW3A3E303 — Motor Control Accessories

VW3A3E303 Modbus Uni-Telway Communication Card, RS485, Obsol

MPNVW3A3E303
Obsolete

Schneider Electric VW3A3E303, Uni-Telway Modbus communication card, 19200 bps, 9-way female SUB-D connector, RS485 physical interface, obsolete.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

VW3A3E303 — Identification
ParameterValue
Product / component typeCommunication card
VW3A3E303 — Cable & Connector
ParameterValue
Connector type9-way female SUB-D connector
VW3A3E303 — Other specifications
ParameterValue
Data format7 bits, odd or even parity, 1 or 2 stop for Modbus ASCII 7 bits, odd or even parity, 1 or 2 stop for Modbus RTU 8 bits, no parity, 2 stop for Modbus RTU 8 bits, odd, even or no parity, 1 stop for Modbus RTU 8 bits, odd parity, 1 stop for Uni-Telway
Display type1 LED for ERR (fault) 1 LED for RUN (status) Graphic display terminal for control word received Graphic display terminal for reference received
Transmission rate4800 bps 9600 bps 19200 bps
Physical interface2-wire RS 485 for Modbus 4-wire RS485 for Modbus 2-wire RS 485 for Uni-Telway
Number of addresses1...147 for Uni-Telway 1...247 for Modbus
Type of polarizationTwo 4.7 kOhm polarization resistors No polarization impedances
Communication serviceCiA 402 profile for Modbus Communication monitoring for Modbus Diagnostics (08) for Modbus I/O profile for Modbus Mirror (FAh) for Uni-Telway Protocol version (30h) for Uni-Telway Read device identification (43) for Modbus Read error counters (A2h) for Uni-Telway Read holding registers (03) for Modbus Read input registers (04) for Modbus Read object (36h) for Uni-Telway Read word (04h) for Uni-Telway Read/write multiple registers (23) for Modbus Reset counters (A4h) for Uni-Telway Write multiple registers (16) for Modbus Write object (37h) for Uni-Telway Write single register (06) for Modbus Write word (14h) for Uni-Telway Identification of the card for Uni-Telway Communication monitoring can be inhibited, fixed
Communication port protocolUni-Telway Modbus RTU Modbus ASCII

Product details

The VW3A3E303 is a communication card from Schneider Electric that provides a Uni-Telway and Modbus RTU/ASCII interface for Altivar drives or other compatible devices. It connects via a 9-way female SUB-D connector and supports 2-wire or 4-wire RS485 physical layers at baud rates of 4800, 9600, or 19200 bps.

The RS485 physical interface (2-wire for Modbus, 4-wire for Modbus, or 2-wire for Uni-Telway) determines the wiring topology. A 2-wire half-duplex bus is standard for Modbus RTU; the 4-wire option supports full-duplex Modbus where needed. The card's data format flexibility — 7 or 8 bits, odd/even/no parity, 1 or 2 stop bits — lets it match the existing bus configuration without a protocol converter. The two LEDs (ERR for fault, RUN for status) and the graphic display terminal signals (control word received, reference received) give on-card diagnostics without a separate tool.

Frequently asked questions

How do I get current pricing and availability for VW3A3E303?

Submit an RFQ. We source the VW3A3E303 through independent distribution channels and confirm current pricing and availability at quote time.

What is VW3A3E303's listed data format?

The card supports 7 bits with odd or even parity and 1 or 2 stop bits for Modbus ASCII; 8 bits with no parity and 2 stop bits for Modbus RTU; 8 bits with odd, even, or no parity and 1 stop bit for Modbus RTU; and 8 bits with odd parity and 1 stop bit for Uni-Telway.

What is VW3A3E303's listed display type?

The card has one LED for ERR (fault), one LED for RUN (status), and graphic display terminal signals for control word received and reference received.

MPN
VW3A3E303