Specifications

VW3A46101 — Identification
ParameterValue
Product typePassive filter
VW3A46101 — Input / Supply
ParameterValue
Rated supply voltage range400 V +/- 10 %
Network number of phases3 phases
VW3A46101 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP20 IP55 (enclosure mounting)
VW3A46101 — Environmental
ParameterValue
Operating ambient temperature45...60 °C (with current derating 3 % per °C) 5...45 °C (without current derating)
Operating altitude> 1000...4000 m with current derating 5 % per 1000 m
Relative humidity5...85 % without condensation
Storage / transport temperature-25...55 °C storage in original packaging -25...65 °C during transport
Vibration resistance2 mm peak to peak (f= 5...13.2 Hz) conforming to IEC 60068-2-6 0.7 gn (f= 13.2...150 Hz) conforming to IEC 60068-2-6
VW3A46101 — Approvals
ParameterValue
Standards complianceIEC 61000-3-4 IEC 61000-2-2 G5/4 engineering recommendation IEC 61000-3-12 IEC 61000-3-2 IEC 61000-2-4

Product details

The Schneider VW3A46101 is a passive harmonic filter designed to reduce current harmonics on the input side of variable speed drives. It's rated at 6 A input and 6.2 A output, on a 400 V +/- 10 % three-phase supply, and mounts one per drive for motors from 0.75 kW up to 3 kW across the ATV61, ATV71, ATV630, ATV650, ATV930, and ATV950 families.

Lifecycle reality — obsolete, but sourced

Schneider lists the VW3A46101 as obsolete.

The filter is IP20 rated for panel mounting, with an IP55 option when enclosure-mounted. Above 1000 m altitude, derate 5 % per additional 1000 m. Terminals accept 0.5 to 10 mm² on the main power connections and 2.5 mm² on the control terminals — spring-cage, so strip length and ferrule sizing matter for a clean install. Vibration resistance is tested to IEC 60068-2-6: 2 mm peak-to-peak from 5 to 13.2 Hz, and 0.7 gn from 13.2 to 150 Hz. That's standard for industrial panel mounting on a machine frame or wall.

Frequently asked questions

Where can I buy VW3A46101?

The VW3A46101 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What drives does the VW3A46101 fit?

It fits one per drive on ATV61W, ATV61H, ATV71H, ATV71P, ATV71W, ATV630, ATV650, ATV930, and ATV950 drives for motors rated 0.75 kW to 3 kW.

What is the THDI of the VW3A46101?

The THDI is 10 % on ATV61W, ATV630, ATV650, ATV930, and ATV950 drives, and 16 % on ATV61H, ATV71H, ATV71P, and ATV71W drives, all in the 0.75 to 3 kW motor range.

What standards does the VW3A46101 comply with?

It complies with IEC 61000-3-4, IEC 61000-2-2, G5/4 engineering recommendation, IEC 61000-3-12, IEC 61000-3-2, and IEC 61000-2-4.

MPN