Skip to main content
Schneider Electric VW3A46130 — AC Drive (VFD) 480V

Schneider VW3A46130 Altivar passive filter, 105 A, 400 V, 50 Hz

MPNVW3A46130
Active

Schneider Electric Altivar VW3A46130 passive filter, 105 A, 400 V, 50 Hz, THDI 10% for 55 kW/75 hp drives, IP20, for Altivar 71/61/Process ATV600/ATV900.

$11,939.73Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

VW3A46130 — Identification
ParameterValue
Product typePassive filter
VW3A46130 — Input / Supply
ParameterValue
Rated supply voltage range400 V +/- 10 %
Network number of phases3 phases
VW3A46130 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP20 IP55 (enclosure mounting)
VW3A46130 — Environmental
ParameterValue
Operating ambient temperature45...60 °C (with current derating 3 % per °C) 5...45 °C (without current derating)
Operating altitude> 1000...4000 m with current derating 5 % per 1000 m
Relative humidity5...85 % without condensation
Storage / transport temperature-25...55 °C storage in original packaging -25...65 °C during transport
Vibration resistance2 mm peak to peak (f= 5...13.2 Hz) conforming to IEC 60068-2-6 0.7 gn (f= 13.2...150 Hz) conforming to IEC 60068-2-6
VW3A46130 — Approvals
ParameterValue
Standards complianceIEC 61000-3-2 G5/4 engineering recommendation IEC 61000-2-4 IEC 61000-3-12 IEC 61000-3-4 IEC 61000-2-2

Product details

Overview

The VW3A46130 is a Schneider Altivar passive filter rated 105 A at 400 V three-phase, 50 Hz, designed to reduce current harmonics on Altivar 71, 61, Process ATV600, and Process ATV900 drives. It delivers a THDI of 10 % for 55 kW/75 hp motor loads on ATV61H, ATV71H, and ATV71W drives, and 5 % for ATV61W at the same power, with a power factor of 1 and 98 % efficiency.

Schneider discontinued the VW3A46130 on 2024-07-22; it is no longer in active production and must be sourced through surplus or broker channels. For new builds or replacements requiring a current-model filter, the VW3A46131 is a functional peer rated 144 A with a THDI of 5 % for 75 kW/100 hp drives, but verify terminal sizing and panel fit before substitution.

Compared to the VW3A46131, the VW3A46130 is rated for a lower switching current (101 A vs 144 A) and targets 55 kW/75 hp drives rather than 75 kW/100 hp, with a higher THDI (10 % vs 5 %) on the same drive families.

MPN
VW3A46130