Skip to main content
Schneider Electric VW3A46162

Schneider VW3A46162 Passive Filter, 26 A, 480 V, 60 Hz, for

MPN VW3A46162
Active

Schneider Electric Altivar series passive filter, VW3A46162, 26 A output, 480 V ±10 %, 60 Hz, for harmonic reduction on variable speed drives.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

VW3A46162 specifications
ParameterValue
Main product or component typePassive filter
IP ratingIP20 / IP55
Temp storage max65 °C
Temp storage min-25 °C
Temp operating max60 °C
Temp operating min5 °C
Cos phi1 (150 % of line current) 0.85 (75 % of line current) 0.99 (100 % of line current)
Efficiency98%
Operating temperature45...60 °C (with current derating 3 % per °C) 5...45 °C (without current derating)

Product details

The VW3A46162 is a passive filter from the Altivar accessory range, designed to reduce current harmonics on variable-speed drives. It is rated for 25 A input and 26 A output at 480 V ±10 %, 60 Hz ±2 %, three-phase. Efficiency sits at 98 %, with thermal losses of 298 W that must be ventilated in the enclosure.

Mounting is one filter per drive, sized for 15 kW / 20 hp motors across the ATV61H, ATV71H, ATV61W, ATV71W, ATV650, ATV630, ATV950, and ATV930 wall-mount series. The IP20 enclosure suits panel mounting; IP55 is achievable with enclosure mounting. Terminals accept 0.5–10 mm² on the main power connections and 2.5 mm² on the A/B terminals. Vibration resistance per IEC 60068-2-6: 2 mm peak-to-peak at 5–13.2 Hz, 0.7 gn at 13.2–150 Hz.

THDI performance depends on the drive model: 10 % for ATV61H and ATV71H (15 kW/20 hp), 10 % for ATV71W (15 kW/20 hp), and 5 % for ATV61W, ATV650, ATV630, ATV950, and ATV930 (all 15 kW/20 hp). The filter complies with IEC 61000-3-12, IEC 61000-3-2, IEC 61000-2-2, G5/4 engineering recommendation, IEC 61000-2-4, and IEC 61000-3-4. Power factor varies with load: cos φ of 1 at 150 % line current, 0.85 at 75 %, and 0.99 at 100 %.

Ambient operating temperature is 5–45 °C without derating; above 45 °C up to 60 °C, derate current by 3 % per °C. Altitude derating applies above 1000 m: 5 % per 1000 m up to 4000 m. Relative humidity 5–85 % without condensation.

Class F electrical insulation. Overload capability: 1.5 × nominal current for 60 seconds — useful for motor starting transients. The filter is a passive type, meaning no active switching components; reliability depends on the inductor and capacitor bank, both rated for continuous duty at the 26 A output.

MPN
VW3A46162