Schneider Electric VW3A4676 — AC Drive (VFD) 480V

Schneider VW3A4676 Passive Filter, 217 A, 480 V, 60 Hz, Obso

MPNVW3A4676
Obsolete

Schneider Electric Altivar series passive harmonic filter, VW3A4676, 217 A rated current, 480 V ±10%, 60 Hz ±5%, 3-phase, IP20, 98% efficiency, obsolete.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

VW3A4676 — Identification
ParameterValue
Product typePassive filter
VW3A4676 — Input / Supply
ParameterValue
Rated supply voltage range480 V +/- 10 %
Network number of phases3 phases
VW3A4676 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP20
VW3A4676 — Environmental
ParameterValue
Operating ambient temperature40...55 °C (with current derating 3 % per °C) 5...40 °C (without current derating)
Operating altitude> 1000...4000 m with current derating 5 % per 1000 m
Relative humidity5...85 % without condensation
Storage / transport temperature-25...55 °C

Product details

The Schneider VW3A4676 is a passive harmonic filter designed for Altivar ATV61 and ATV71 variable-speed drives. Its job is to knock down current harmonics drawn by the drive to 5 % THDI when paired with ATV61HC13N4 (132 kW/200 hp motor), ATV61HC25N4 (250 kW/400 hp), ATV71HC13N4 (132 kW/200 hp), or ATV71HC25N4 (250 kW/400 hp). That 5 % THDI figure means the filter brings the drive's input current distortion well below IEEE 519-2014 recommended limits for most industrial service entrances — no need for a 12-pulse or active front end on these frame sizes. Rated for 217 A continuous at 480 V ±10 %, 60 Hz ±5 %, three-phase input. Efficiency hits 98 %, so only about 2 % of the pass-through power is lost as heat. Power factor correction is built in: cos φ sits at 0.99 at full load, 0.85 at 75 % load, and unity (1.0) at 150 % of line current — useful for meeting utility PF penalties on larger pump and fan drives. The filter is IP20 rated — intended for enclosure mounting, not exposed washdown. Ambient operation is 5...40 °C without derating; above that, derate 3 % per °C up to 55 °C. Altitude derating kicks in above 1000 m at 5 % per 1000 m. Installation is straightforward: bare-wire connection up to 16.5 mm diameter, one filter per drive on the smaller frames, two in parallel for the 250 kW units.

Frequently asked questions

What is VW3A4676's listed THDI?

The VW3A4676 achieves 5 % THDI when paired with ATV61HC13N4 (132 kW/200 hp motor), ATV61HC25N4 (250 kW/400 hp), ATV71HC13N4 (132 kW/200 hp), or ATV71HC25N4 (250 kW/400 hp).

What is VW3A4676's rated current and voltage?

The filter is rated for 217 A continuous at 480 V ±10 %, 60 Hz ±5 %, three-phase.