Skip to main content
Schneider Electric VW3AP0276

VW3AP0276 Automated Mains Disconnect, ATV600/900, 710-800kW

MPN VW3AP0276
Active

Schneider Electric Altivar Process ATV600/ATV900 series, automated mains disconnect, VW3AP0276, for drive systems 710 and 800kW, cannot be ordered alone.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

VW3AP0276 specifications
ParameterValue
Accessory separate part typeAutomated main switch disconnect

Product details

Automated Mains Disconnect for High-Power ATV Drives

The VW3AP0276 is an automated mains disconnect accessory for the Altivar Process ATV600 and ATV900 drive families, sized for drive systems rated 710 and 800 kW. It serves as the line-side switching element that isolates the drive from the supply under load or fault conditions — effectively a motor-rated disconnect that can be integrated into the drive system's control logic rather than requiring a separate manual handle.

Sourcing Constraint: Enclosure Required

A critical procurement constraint: the VW3AP0276 cannot be ordered alone. It is only available in combination with a standard enclosure. This means the disconnect ships as part of a pre-assembled drive system package — not as a standalone component for field retrofits. If your BOM calls for this order code as a separate line item, verify that the enclosure is already specified on the drive system order; otherwise the distributor cannot fulfil the line.

Deployment Context: Drive System Integration

Designed for the compact drive system architecture of the ATV600 and ATV900 series, the VW3AP0276 mounts inside the standard enclosure that houses the drive itself. It handles the automated break-before-make sequence that protects the drive DC bus capacitors from inrush on power-up and provides a controlled disconnect on power-down. For a panel builder or system integrator, this means the disconnect is already wired into the drive's control circuit — no separate contactor or manual switch needs to be added upstream.

The VW3AP0276 has a lifecycle stage of mature and an active product status, indicating steady-state production. No end-of-life notification exists.

MPN
VW3AP0276