Skip to main content
Schneider Electric VW3AP3204 — Motor Control Accessories

Schneider Electric VW3AP3204 Altivar Relay Output Module, 3

MPNVW3AP3204
Active

Schneider Electric Altivar series, additional output module VW3AP3204, 3 relay outputs, screw terminal, 5 A resistive / 2 A inductive switching.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

VW3AP3204 — Identification
ParameterValue
Product / component typeAdditional output module
Conditions of useCannot be ordered alone, only possible in combination with a standard enclosure

Cable & Connector

VW3AP3204 — Cable & Connector
ParameterValue
Electrical connectionScrew terminal block, 1.5 mm² / AWG 16, 0.5 N.m

Other specifications

VW3AP3204 — Other specifications
ParameterValue
Input (output type)3 relay output
Discrete output type(R4, R5, R6) relay normally open, sampling time: 1 ms
Electrical durability100000 cycles
Discrete output number3
Maximum switching current2 A at 250 V AC on inductive load, cos phi = 0.4 and L/R = 5 ms 2 A at 30 V DC on inductive load, cos phi = 0.4 and L/R = 5 ms 5 A at 250 V AC on resistive load, cos phi = 1 and L/R = 5 ms 5 A at 30 V DC on resistive load, cos phi = 1 and L/R = 5 ms
Minimum switching current5 mA at 24 V DC

Product details

The Schneider Electric VW3AP3204 is a 3-relay output expansion module for Altivar variable-speed drives. It adds three normally-open relay outputs (R4, R5, R6) with a 1 ms sampling time, letting the drive signal external contactors, brakes, or status lamps without pulling extra I/O from the controller. This module cannot be ordered alone — it mounts inside a standard Altivar enclosure as a factory-installed or field-fit option. Plan for the enclosure when sourcing.

Each relay switches up to 5 A at 250 V AC on resistive loads (cos φ = 1) and 2 A on inductive loads (cos φ = 0.4, L/R = 5 ms). On DC, the same 5 A / 2 A split applies at 30 V. The minimum switching current is 5 mA at 24 V DC — useful for low-power PLC inputs or pilot lights. Rated for 100,000 electrical cycles. That covers most conveyor or fan cycling in a production line; for high-frequency switching (e.g., rapid jogging), consider a solid-state output module instead. Connection is via screw terminals accepting 1.5 mm² / AWG 16 wire, torqued to 0.5 N·m. Standard panel practice — no special tooling needed.

Frequently asked questions

Can I order VW3AP3204 by itself?

No — it must be ordered in combination with a standard Altivar enclosure. It is not a standalone module.

What is the maximum switching current on the relays?

5 A at 250 V AC on resistive loads, 2 A at 250 V AC on inductive loads (cos φ = 0.4). On DC, 5 A at 30 V DC resistive, 2 A at 30 V DC inductive.

Where can I buy VW3AP3204 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
VW3AP3204