Skip to main content
Schneider Electric VW3SKLN090H400 — AC Drive (VFD) 600V

Schneider Altivar VW3SKLN090H400 Line Choke, 90 A, 400 mH, O

MPNVW3SKLN090H400
Obsolete

Schneider Altivar series line choke, 3-phase, 90 A rated current, 400 mH inductance, 690V, for variable speed drive harmonic reduction.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

VW3SKLN090H400 — Identification
ParameterValue
Product range / seriesAltivar
Product / component typeLine choke
VW3SKLN090H400 — Electrical (input)
ParameterValue
Number of phases3 phases
VW3SKLN090H400 — Mechanical
ParameterValue
Terminal / wiring connectionTerminal 6 mm² / AWG 8, 0.8...1 N.m
VW3SKLN090H400 — Environmental
ParameterValue
IP rating (with kit options)Choke: IP00 Terminals: IP20
Operating ambient temperature45...55 °C (with current derating of 2 % per °C) 0...45 °C (without current derating)
Storage temperature-25...70 °C
Operating altitude (with derating)1000...3000 m with current derating 1 % per 100 m
Relative humidity0...95 %
Pollution degree2 conforming to EN 50178
Environmental resistance classes3B1 conforming to IEC 721-3-3 3C2 conforming to IEC 721-3-3 3S1 conforming to IEC 721-3-3
Vibration resistance1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6 1.5 mm peak to peak (f= 3...13 Hz) conforming to IEC 60068-2-6
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
VW3SKLN090H400 — Approvals & Compliance
ParameterValue
StandardsVDE 0160 level 1 IEC 60076 (with HD398) EN 50178

Product details

The Schneider Altivar VW3SKLN090H400 is a 3-phase line choke rated at 90 A with 400 mH inductance, designed for variable speed drive applications to reduce current harmonics. Rated for 690V systems at 50/60 Hz, this choke handles 1.65x nominal current for 60 seconds — enough headroom for motor inrush during acceleration. Voltage drop stays at 5% maximum at rated load, so the drive sees line voltage within tolerance.

Above 45 °C up to 55 °C, derate 2% per °C. 400 mH inductance defines the impedance at line frequency — this is what attenuates the harmonic currents drawn by the drive's rectifier stage. Higher inductance gives better filtering but more voltage drop; 5% drop at rated load is typical for a line choke sized to meet IEC harmonic limits. Terminal accepts up to 6 mm² / AWG 8 wire with 0.8 to 1 N·m torque.

This line choke sits between the mains supply and a variable speed drive input. Its job is to smooth the current waveform, reduce harmonic distortion, and protect the drive's DC bus capacitors from excessive ripple current. Class F insulation handles the thermal load.

Frequently asked questions

What standards does VW3SKLN090H400 comply with?

It complies with VDE 0160 level 1, IEC 60076 (with HD398), and EN 50178. Creepage distance is 11.5 mm per IEC 60664, clearance is 5.5 mm, and pollution degree is 2 per EN 50178.

Where can I buy VW3SKLN090H400?

We can source it against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
VW3SKLN090H400