The VW3SKLN125H270: The 125 A [In] rated current is the continuous RMS current the choke can carry without exceeding its thermal rise — sized for a drive input that draws up to that nominal current. The 0.27 mH inductance value determines the impedance at line frequency (50...60 Hz) and therefore the voltage drop and harmonic attenuation; at 50 Hz, the inductive reactance is about 0.085 Ω, producing roughly 10.6 V drop at 125 A (about 2.5 % of a 400 V line). The 87 W thermal losses mean that heat must be dissipated from the open frame (IP00) into the surrounding enclosure — the choke is not self-ventilated and relies on the panel's airflow. The IP00 rating means no protection against dust ingress or water — the choke must be mounted inside a clean, dry enclosure or cabinet. The 1.5 x nominal current overload capability for 60 seconds allows it to ride through short-duration drive inrush or motor acceleration without saturating the core.
Schneider Altivar VW3SKLN125H270 Line Choke, 125 A, 0.27 mH
Schneider Altivar series, line choke VW3SKLN125H270, 125 A rated current, 0.27 mH inductance, 3-phase, IP00 open-frame.
Specifications
| Parameter | Value |
|---|---|
| Product / component type | Line choke |
| Product range | Altivar |
| Parameter | Value |
|---|---|
| Rated current (In) | 125 A |
| Parameter | Value |
|---|---|
| Width | 310 mm |
| Height | 370 mm |
| Depth | 200 mm |
| Parameter | Value |
|---|---|
| IP protection rating | IP00 |
| Parameter | Value |
|---|---|
| Conformance standards | EN 50178 |
| Parameter | Value |
|---|---|
| Max current | 1.5 x nominal current (duration = 60 s) |
| Thermal losses | 87 W |
| Phases | 3 phases |
| Device application | Reduction of current harmonics |
| Value of inductance | 0.27 mH |
| Power supply frequency | 50...60 Hz |
Product details
Frequently asked questions
Where can I buy VW3SKLN125H270 and what is the price?
The VW3SKLN125H270 is sourced to order through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.
What compliance documentation does VW3SKLN125H270 carry?
The VW3SKLN125H270 is listed to EN 50178, the standard for electronic equipment used in power installations. No RoHS, REACH, UL, or IEC certs are recorded in the available documentation.
What are the key ratings of VW3SKLN125H270?
125 A rated current, 0.27 mH inductance, 87 W thermal losses, IP00 open-frame enclosure, 3-phase, 50/60 Hz line frequency, and a 60-second overload capability of 1.5 x nominal current.