Skip to main content
Schneider Electric VW3SKLN160H225 — Motor Control Accessories

Schneider Altivar VW3SKLN160H225 Line Choke, 160 A, 0.225 mH

MPNVW3SKLN160H225
Obsolete

Schneider Electric Altivar series, VW3SKLN160H225, line choke, 160 A rated current, 0.225 mH inductance, 3-phase, IP00, 104 W thermal losses.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

VW3SKLN160H225 — Identification
ParameterValue
Product / component typeLine choke
Product rangeAltivar
VW3SKLN160H225 — Electrical
ParameterValue
Rated current (In)160 A
VW3SKLN160H225 — Mechanical
ParameterValue
Width316 mm
Height370 mm
Depth200 mm
VW3SKLN160H225 — Environmental
ParameterValue
IP protection ratingIP00
VW3SKLN160H225 — Approvals
ParameterValue
Conformance standardsEN 50178
VW3SKLN160H225 — Other specifications
ParameterValue
Max current1.5 x nominal current (duration = 60 s)
Thermal losses104 W
Phases3 phases
Device applicationReduction of current harmonics
Value of inductance0.225 mH
Power supply frequency50...60 Hz

Product details

What this line choke does

The VW3SKLN160H225 is a 3-phase line choke (line reactor) from the Schneider Altivar accessory range, rated at 160 A continuous with 0.225 mH inductance. It sits between the mains supply and a variable-frequency drive to reduce current harmonics, smooth line transients, and limit peak inrush currents during power-up. The 0.225 mH value is sized for a 160 A drive input — the inductance limits the rate of rise of fault current and keeps harmonic distortion within the drive's design envelope.

Rated at 160 A continuous, this choke matches the input of a 160 A Altivar drive frame. The 0.225 mH inductance value is the one that governs harmonic attenuation — too low and the choke doesn't filter; too high and voltage drop across the reactor starves the drive DC bus. Thermal losses of 104 W mean the choke dissipates heat into the enclosure; panel builders need to account for that in the cabinet thermal budget. The IP00 open-frame construction means it's not touch-safe — it goes inside a locked electrical enclosure, not in a washdown area.

Physical integration

The choke measures 316 mm wide × 370 mm high × 200 mm deep. It's a bolted-down component — no DIN-rail clip. The IP00 rating means it's an open-frame reactor; plan for top/bottom clearance for airflow and cable entry. The 104 W thermal loss needs ventilation or forced air in a sealed cabinet. Three-phase line and load connections are the standard power terminals; no control wiring.

Frequently asked questions

Where can I buy VW3SKLN160H225 and get a price?

We source and quote this part to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm number.

What are the key specifications of VW3SKLN160H225?

Rated current 160 A, inductance 0.225 mH, 3-phase, 50/60 Hz, thermal losses 104 W, IP00 open-frame, dimensions 316 × 370 × 200 mm, compliant with EN 50178.

MPN
VW3SKLN160H225