Specifications

WB1EA048 — Identification
ParameterValue
Product rangeTeSys
Product or component typeContactor coil
WB1EA048 — Electrical
ParameterValue
Control circuit voltage [Uc]48 V AC 50 Hz 53 V AC 60 Hz
Control circuit typeAC
Control circuit voltage limitsOperational: 0.85...1.1 Uc at 50 Hz (at Operational: 0.85...1.1 Uc at 60 Hz (at <131 °F (55 °C))
Inrush power220...270 VA 50 Hz 0.4 68 °F (20 °C)) 225...275 VA 60 Hz 0.34 68 °F (20 °C))
Hold-in power consumption35...55 VA 50 Hz 0.34 68 °F (20 °C)) 35...55 VA 60 Hz 0.37 68 °F (20 °C))
WB1EA048 — Other specifications
ParameterValue
Coil typeLow consumption
Inrush power in90...110 W 68 °F (20 °C) 75...95 W 68 °F (20 °C)
Average resistance2.22 Ohm 68 °F (20 °C)
Inductance of closed circuit0.15 H
Hold-in power consumption in13...19 W 68 °F (20 °C) 10...13 W 68 °F (20 °C)

Product details

The Schneider Electric TeSys WB1EA048 is a low-consumption contactor coil designed for the CV1B and CV3B contactor frames. It operates on 48 V AC at 50 Hz or 53 V AC at 60 Hz, with a control circuit voltage tolerance of 0.85 to 1.1 Uc at 50/60 Hz below 55 °C. This is a replacement coil, not a complete contactor — you swap it into the existing contactor assembly when the original coil fails or the control voltage needs changing.

The coil draws 90 to 110 W inrush at 20 °C (75 to 95 W on the lower end of the range), and holds in at 13 to 19 W. Inrush VA is 220 to 270 VA at 50 Hz, 225 to 275 VA at 60 Hz. The average DC resistance is 2.22 ohms at 20 °C, and the closed-circuit inductance is 0.15 H. These numbers matter for sizing the control transformer and the fuse or circuit breaker feeding the contactor — the inrush surge is brief but significant, so the protection must be slow-blow or set to ride through the pickup transient. The low-consumption coil design means the hold-in power is roughly one-seventh of the inrush, which keeps the coil temperature down in continuous-duty applications.

Frequently asked questions

What contactors does the WB1EA048 coil fit?

It is designed for the Schneider TeSys CV1B and CV3B contactor frames. These are the direct-fit applications; the coil mounts onto the contactor magnet assembly and is held by the standard clip or screw arrangement.

What control voltage does the WB1EA048 require?

The coil operates on 48 V AC at 50 Hz or 53 V AC at 60 Hz. The control circuit voltage tolerance is 0.85 to 1.1 Uc at both frequencies, provided the ambient temperature stays below 55 °C.

How is the WB1EA048 sourced given it is obsolete?

It is sourced to order against an RFQ from our surplus and last-time-buy inventory. There is no factory lead time because production has ended; the availability depends on what stock we hold. Submit an RFQ for current availability and pricing.

MPN
WB1EA048