Skip to main content
Schneider Electric WB1EA400 — Reversing Contactors

WB1EA400 TeSys contactor coil, 400VAC/440VAC, obsolete

MPNWB1EA400
Obsolete

Schneider Electric TeSys range, WB1EA400 contactor coil, 400 V AC 50 Hz / 440 V AC 60 Hz, low consumption type, for CV1B and CV3B contactors.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

WB1EA400 specifications
ParameterValue
Coil typeLow consumption
Control circuit typeAC
Product or component typeContactor coil
Coil voltage440 V AC 60 Hz 400 V AC 50 Hz
Control circuit voltage limitsOperational: 0.85...1.1 Uc at 50 Hz (at Operational: 0.85...1.1 Uc at 60 Hz (at <131 °F (55 °C))
Inrush power in90...110 W 68 °F (20 °C) 75...95 W 68 °F (20 °C)
Hold-in power consumption in13...19 W 68 °F (20 °C) 10...13 W 68 °F (20 °C)
RangeTeSys
Category18402-WORLD SERVICE PARTS(CONTROL ACCESS)
Average resistance182 Ohm 68 °F (20 °C)
Inductance of closed circuit10 H

Product details

The WB1EA400 is a replacement coil from the Schneider Electric TeSys range, designed specifically for the CV1B and CV3B contactor frames. It is a low-consumption AC coil rated at 400 V AC 50 Hz and 440 V AC 60 Hz, meaning it holds the contactor closed on a 50 Hz supply at 400 V and on a 60 Hz supply at 440 V — the two common line voltages across European and North American industrial plants. The coil draws an inrush of 90 to 110 W at 20 °C, settling to a hold-in consumption of 13 to 19 W at the same temperature, which keeps the thermal load on the panel wiring manageable provided the contactor is in a ventilated enclosure.

Electrical characteristics for the panel builder

The coil's average resistance is 182 ohms at 20 °C, and its closed-circuit inductance is 10 H. The control circuit voltage limits are 0.85 to 1.1 times Uc at both 50 Hz and 60 Hz, provided the ambient temperature stays below 55 °C. Inrush power in VA is 220 to 270 VA at 50 Hz and 225 to 275 VA at 60 Hz, with a power factor of 0.4 and 0.34 respectively. Hold-in VA drops to 35 to 55 VA at both frequencies. These numbers matter for sizing the control transformer and the fuse or circuit breaker feeding the contactor coil circuit — the inrush peak is brief but must not sag the control bus below the dropout threshold of other coils on the same circuit.

Frequently asked questions

What contactors does the WB1EA400 fit?

The WB1EA400 is a replacement coil for the Schneider Electric CV1B and CV3B contactor frames. It is part of the TeSys range.

What is the control voltage of the WB1EA400?

The coil is rated at 400 V AC at 50 Hz and 440 V AC at 60 Hz. It operates within 0.85 to 1.1 times Uc at both frequencies, up to 55 °C ambient.

How do I source the WB1EA400 if it is obsolete?

Because the part is obsolete and not in standard distribution, we source it on request from the independent surplus and broker market. Submit an RFQ; we search our network for verified inventory and quote you the best available option.

MPN
WB1EA400