Skip to main content
Schneider Electric WB1HA440 — Reversing Contactors

Schneider Electric WB1HA440 TeSys Contactor Coil, 440V AC 50

MPNWB1HA440
Obsolete

Schneider Electric TeSys range, contactor coil WB1HA440, 440V AC 50Hz / 500V AC 60Hz, low consumption type.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

WB1HA440 — Identification
ParameterValue
Product rangeTeSys
Product or component typeContactor coil
WB1HA440 — Electrical
ParameterValue
Control circuit voltage [Uc]440 V AC 50 Hz 500 V AC 60 Hz
Control circuit typeAC
Control circuit voltage limitsOperational: 0.85...1.1 Uc at 50 Hz (at Operational: 0.85...1.1 Uc at 60 Hz (at <131 °F (55 °C))
Inrush power500...615 VA 50 Hz 0.31 2P 68 °F (20 °C)) 560...675 VA 60 Hz 0.3 2P 68 °F (20 °C))
Hold-in power consumption60...85 VA 50 Hz 0.38 68 °F (20 °C)) 65...95 VA 60 Hz 0.39 68 °F (20 °C))
WB1HA440 — Other specifications
ParameterValue
Coil typeLow consumption
Inrush power in155...190 W 68 °F (20 °C) 2P 170...200 W 68 °F (20 °C) 2P
Average resistance78.1 Ohm 68 °F (20 °C)
Inductance of closed circuit7.1 H
Hold-in power consumption in22...35 W 68 °F (20 °C) 25...40 W 68 °F (20 °C)

Product details

The WB1HA440 is a low-consumption contactor coil from the Schneider Electric TeSys range, designed to mate with CV1B and CV3B contactors. It's the replacement coil you'd order when the original on a TeSys contactor in the field fails — not a standalone part, but the service component that keeps the contactor running. Rated for 440 V AC at 50 Hz and 500 V AC at 60 Hz control circuits, with an operational voltage tolerance of 0.85 to 1.1 times Uc at those frequencies. That means it holds in reliably on a nominal 440V line even if the supply sags to 374V or rises to 484V.

Key ratings for fit verification

Inrush power draw is 155 to 190 W at 20 °C (170 to 200 W for the 2P variant), with inrush VA of 500 to 615 VA at 50 Hz and 560 to 675 VA at 60 Hz. Hold-in power settles to 22 to 35 W (25 to 40 W) and 60 to 95 VA depending on frequency. Average coil resistance is 78.1 ohms at 20 °C, and the closed-circuit inductance is 7.1 H. These numbers matter for sizing the control transformer and verifying the contactor's pick-up curve against your supply.

Frequently asked questions

What contactors does the WB1HA440 coil fit?

It is designed for Schneider Electric TeSys CV1B and CV3B contactors.

What is the control voltage for the WB1HA440?

440 V AC at 50 Hz or 500 V AC at 60 Hz, with an operational range of 0.85 to 1.1 times Uc.

How do I source the WB1HA440 if it's obsolete?

Since it's obsolete with no direct replacement, sourcing is through surplus or independent distributor channels. Submit an RFQ for current availability and pricing.

MPN
WB1HA440