Skip to main content
Schneider Electric WB1JB335 — Reversing Contactors

TeSys WB1JB335 Contactor Coil, 220V AC 50Hz, Obsolete

MPNWB1JB335
Obsolete

TeSys range, contactor coil WB1JB335, 220V AC 50Hz, low consumption type for CV1B/CV3B contactors, obsolete.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

WB1JB335 — Identification
ParameterValue
Product rangeTeSys
Product or component typeContactor coil
WB1JB335 — Electrical
ParameterValue
Control circuit voltage [Uc]220 V AC 50 Hz
Control circuit typeAC
Control circuit voltage limitsOperational: 0.85...1.1 Uc at 50 Hz (at <131 °F (55 °C))
Inrush power700...840 VA 0.17 68 °F (20 °C))
Hold-in power consumption80...110 VA 50 Hz 0.38 68 °F (20 °C))
WB1JB335 — Other specifications
ParameterValue
Coil typeLow consumption
Inrush power in120...145 W 68 °F (20 °C)
Average resistance6.29 Ohm 68 °F (20 °C)
Inductance of closed circuit1.37 H
Hold-in power consumption in28...45 W 68 °F (20 °C)

Product details

The WB1JB335 is a low-consumption contactor coil from the TeSys range, wound for 220 V AC at 50 Hz control voltage. It is the replacement coil for CV1B and CV3B contactors — the exact part a line-down situation calls for when that contactor's coil fails and the machine builder's BOM lists this order code. At 68 °F (20 °C) the inrush power draw is 120...145 W (700...840 VA, power factor 0.17), dropping to a hold-in consumption of 28...45 W (80...110 VA, power factor 0.38). The closed-circuit inductance is 1.37 H, and average coil resistance measures 6.29 Ω. These numbers matter for sizing the control transformer and verifying the upstream fuse or breaker doesn't nuisance-trip on the inrush peak. The control voltage limits are 0.85...1.1 Uc at 50 Hz, up to 131 °F (55 °C) ambient — so the coil holds in reliably down to 187 V AC and picks up at the full 220 V nominal. If your panel runs hot or the line voltage sags, this gives the operating window.

Frequently asked questions

What contactors does the WB1JB335 coil fit?

It is the replacement coil for CV1B and CV3B contactors in the TeSys range.

What is the control voltage and frequency for this coil?

220 V AC at 50 Hz. The operational voltage range is 0.85 to 1.1 times Uc at 50 Hz, up to 55 °C ambient.

How do I source an obsolete WB1JB335 coil?

Through an RFQ to a distributor that handles surplus and hard-to-find industrial automation parts. No stock or lead time is published; each order is quoted individually.

MPN
WB1JB335