Skip to main content
Schneider Electric WB1KB122

Schneider TeSys WB1KB122 Contactor Coil, 240V AC/220-250V DC

MPN WB1KB122
Obsolete

Schneider Electric TeSys WB1KB122 low-consumption contactor coil, 240 V AC 50-400 Hz / 220-250 V DC control circuit, 25 ms sealed operating time, 1.2M mechanical cycles.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

WB1KB122 specifications
ParameterValue
Coil typeLow consumption
Control circuit typeDC AC
Main product or component typeContactor coil
Coil voltage240 V AC 50...400 Hz 220...250 V DC
Mechanical life cycles1200000 cycles
Operating time25 ms sealed

Product details

The Schneider Electric TeSys WB1KB122 is a low-consumption contactor coil designed for the TeSys range of contactors. It operates on a dual-rated control circuit: 240 V AC at 50-400 Hz or 220-250 V DC, with a sealed operating time of 25 ms and mechanical durability rated at 1,200,000 cycles. The coil draws inrush power between 380-1400 W depending on the number of poles, but hold-in consumption drops to just 0.15-1.6 W — the low-consumption design that keeps the panel cool and reduces continuous draw on the control transformer.

The 240 V AC / 220-250 V DC control voltage means this coil drops into any panel with a standard 240 V control transformer or a 220 V DC bus — common in European and Asian installations. The 25 ms sealed operating time is fast enough for most motor-starting and switching applications, but the maximum operating rate of 120 cycles per minute at 55 °C sets a ceiling for high-speed pick-and-place or indexing lines; sustained faster cycling risks overheating the coil. The 1.2 million mechanical cycles give a solid service life for a contactor in a typical conveyor or pump panel — roughly 5-8 years at moderate duty before the coil or contactor assembly needs attention.

This coil mounts directly onto the TeSys D or TeSys F contactor frame — no adapter bracket needed. The low hold-in power (0.15-1.6 W) means minimal heat rise inside the enclosure, so derating for adjacent components is less of a concern than with standard coils. Verify the control circuit voltage matches the coil rating before installation; the 137-151 V control circuit voltage limits are the dropout and pickup thresholds, not the nominal supply.

MPN
WB1KB122