Skip to main content
Schneider Electric WB1KB155 — Reversing Contactors

Schneider TeSys WB1KB155 Contactor Coil, 47-51 V DC, Obsolet

MPNWB1KB155
Obsolete

Schneider Electric TeSys series, WB1KB155 low-consumption contactor coil, 47...51 V DC control circuit, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

WB1KB155 specifications
ParameterValue
Coil typeLow consumption
Control circuit typeAC
Product or component typeContactor coil
Coil voltage47...51 V DC
Inrush power in450...620 VA 1P
Hold-in power consumption in0.15...0.2 VA 50...400 Hz 1P
Mechanical durability1200000 cycles
RangeTeSys
Category18402-WORLD SERVICE PARTS(CONTROL ACCESS)
Operating time25 ms sealed
Heat dissipation7...10 W 1P
Average resistance4.96 Ohm 68 °F (20 °C)
Maximum operating rate120 cyc/mn 131 °F (55 °C)

Product details

The Schneider Electric TeSys WB1KB155 is a low-consumption contactor coil designed for the TeSys range of contactors. It operates on a 47...51 V DC control circuit, drawing an inrush power of 380...520 W and holding in at just 0.15...0.2 W. The sealed operating time is 25 ms, and it is rated for 1,200,000 mechanical cycles at a maximum operating rate of 120 cycles per minute at 131 °F (55 °C).

The 47...51 V DC control voltage is a narrow band — verify your control supply sits within that range, not just nominally 48 V. The low-consumption design (0.15...0.2 W hold-in) means minimal heat dissipation in the panel, but the inrush spike at 380...520 W still needs a power supply that can deliver that transient without droop. The 25 ms sealed operating time is typical for a contactor coil; it governs how fast the main contacts close, which matters for sequence timing in a motor starter.

Frequently asked questions

What is the closest alternative to the WB1KB155?

There is no official successor order code listed for this coil. A direct replacement would need to match the 47...51 V DC control voltage, low-consumption coil type, and TeSys mounting footprint. Without a manufacturer-specified cross-reference, verify fit by comparing the control circuit voltage and mechanical interface against any candidate part.

What compliance documentation is available for the WB1KB155?

The evidence does not list specific compliance certifications (RoHS, REACH, UL, IEC) for this part. As an obsolete service part, original documentation may be limited; request any available certificates when sourcing.

MPN
WB1KB155