Schneider Electric XCKJ110541 — Limit Switches

Square D XCKJ110541 Heavy Duty Limit Switch, 10A 240VAC, IP6

MPNXCKJ110541

Square D Osiswitch XCKJ110541 heavy duty plug-in limit switch, SPDT, 10A at 240VAC, IP66/NEMA 4/12, UL/CSA.

$183.59Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

XCKJ110541 specifications
ParameterValue
TypeHEAVY DUTY, PLUG IN
Operation typeSPRING RETURN, SNAP ACTION
Connection typePG13.5 CABLE GLAND/SCREW CLAMP TERMINAL
Actuator (Head type)ROTARY HEAD, ADJUSTABLE DELRIN[R] ROLLER LEVER
Contact configurationSPDT
EnclosureNEMA 1/2/4/12, IP66
Operating temperature-13 TO 158 DEG F
Body materialZAMAK[R] ZINC ALLOY
ApprovalUL, CSA
ModelXCKJ
CategoryHeavy Duty Limit Switches
Sub-CategoryGeneral/Heavy Duty Limit Switch
Contact rating240 VAC 10 AMPERE, 250 VDC 0.27 AMPERE
Operating force33.3 OZ-INCH
Manufacturer brandSquare D Co.
Product descriptionTelemecanique XCKJ110541 Limit Switch 600Vac 10Amp Xckj +Options
Additional informationAPPLICABLE STANDARD EN/IEC 60204-1, EN/IEC 60947-5-1
Full technical descriptionHeavy Duty, Plug in Type; SPDT Contact Configuration; PG13.5 Cable Gland/Screw Clamp Terminal Connection Type; Spring Return, Snap Action Operation Type; 240 VAC 10 Ampere, 250 VDC 0.27 Ampere Contact Rating; UL, CSA Approval; NEMA 1/2/4/12, IP66 Enclosure; ZAMAK[R] Zinc Alloy Body Material; -13 to 158 Deg F Operating Temperature; 33.3 oz-Inch Operating Force; Rotary Head, Adjustable DELRIN[R] Roller Lever Actuator/Head Type; OSISWITCH[R] Brand; Applicable Standard En/Iec 60204-1, En/Iec 60947-5-1; XCKJ Model

Product details

The Square D XCKJ110541 is a heavy duty plug-in limit switch from the Osiswitch line, built for industrial environments where reliability under washdown and dust exposure matters. It carries a SPDT contact block rated 10 A at 240 VAC and 0.27 A at 250 VDC — the AC side handles most control-circuit loads on a line, while the DC rating is low enough that you'll want to verify it against your specific solenoid or valve draw before committing the BOM line.

Enclosure and approvals

Rated NEMA 1/2/4/12 and IP66, so it stands up to hose-down cleaning and airborne particulates common on food, beverage, and packaging lines. UL and CSA listed — accepted across North American panels without a secondary evaluation. The ZAMAK zinc alloy body resists corrosion better than painted steel in wet environments.

Actuator and mounting

Rotary head with an adjustable DELRIN roller lever — the lever position can be rotated in 90° increments to match the cam or dog approach angle. Spring-return snap-action operation gives positive break, so it meets the forced-opening requirement of EN/IEC 60947-5-1 for safety circuits. Connection is via a PG13.5 cable gland with screw-clamp terminals; strip length around 8 mm and you're good for 0.2–2.5 mm² stranded or solid.

Frequently asked questions

What approvals does the XCKJ110541 carry?

UL and CSA listed. It also references EN/IEC 60204-1 and EN/IEC 60947-5-1 for safety circuit compliance.

What is the enclosure rating?

NEMA 1/2/4/12 and IP66, meaning it's suitable for indoor use where it may be hosed down or exposed to dust and falling dirt.

What is the contact configuration and rating?

SPDT (one normally-open and one normally-closed set). Rated 10 A at 240 VAC and 0.27 A at 250 VDC.

MPN
XCKJ110541