Skip to main content
Schneider Electric XCKJ50513 — Limit Switches

Square D XCKJ50513 Limit Switch, 240 VAC 10 A, IP66

MPNXCKJ50513

Square D / Telemecanique OsiSwitch XCKJ50513 heavy-duty limit switch, SPDT slow make/break, 240 VAC 10 A / 250 VDC 0.27 A, NEMA 1/2/4/12 IP66, UL CSA.

$127.59Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

XCKJ50513 key specifications
ParameterValue
TypeHEAVY DUTY, NON PLUG IN
Operation typeSPRING RETURN
Connection typePG13.5 CABLE GLAND/SCREW CLAMP TERMINAL
Actuator (Head type)ROTARY HEAD, STEEL ROLLER LEVER
Contact configurationSPDT SLOW MAKE/BREAK
EnclosureNEMA 1/2/4/12, IP66
Operating temperature-13 TO 158 DEG F
Body materialZAMAK[R] ZINC ALLOY
ApprovalUL, CSA
ModelXCKJ
CategoryHeavy Duty Limit Switches
Pretravel23 DEG

All specifications

XCKJ50513 additional specifications
ParameterValue
Sub-CategoryGeneral/Heavy Duty Limit Switch
Total travel90 DEG
Contact rating240 VAC 10 AMPERE, 250 VDC 0.27 AMPERE
Operating force33.3 OZ-INCH
Manufacturer brandSquare D Co.
Differential travel11 DEG
Product descriptionTelemecanique XCKJ50513 Limit Switch 240Vac 10Amp Xckj +Options
Additional informationAPPLICABLE STANDARD EN/IEC 60204-1, EN/IEC 60947-5-1
Full technical descriptionHeavy Duty, Non Plug in Type; SPDT Slow Make/Break Contact Configuration; PG13.5 Cable Gland/Screw Clamp Terminal Connection Type; Spring Return Operation Type; 240 VAC 10 Ampere, 250 VDC 0.27 Ampere Contact Rating; UL, CSA Approval; NEMA 1/2/4/12, IP66 Enclosure; ZAMAK[R] Zinc Alloy Body Material; -13 to 158 Deg F Operating Temperature; 33.3 oz-Inch Operating Force; 11 Deg Differential Travel; Rotary Head, Steel Roller Lever Actuator/Head Type; 23 Deg Pretravel; 90 Deg Total Travel; OSISWITCH[R] Brand; Applicable Standard En/Iec 60204-1, En/Iec 60947-5-1; XCKJ Model
Proposition 65 warningWARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Product details

The Square D / Telemecanique XCKJ50513 is a heavy-duty, non-plug-in limit switch from the OsiSwitch line, built for position sensing on industrial machinery where the environment is wet, dusty, or sees washdown. The ZAMAK zinc-alloy body and NEMA 1/2/4/12 / IP66 enclosure mean this switch survives on conveyor lines, packaging machines, and material-handling equipment where a standard limit switch would corrode or let moisture in. The rotary head with a steel roller lever gives it a 23-degree pretravel and 90-degree total travel, with 11 degrees of differential travel before the contacts reset — figures that matter when you are setting up cam-actuated position detection on a transfer station or a gate. The contact block is SPDT slow make/break, rated at 240 VAC 10 A and 250 VDC 0.27 A. That DC rating is the real constraint for most control circuits — if you are switching a DC solenoid or a PLC input at 24 VDC, verify the inrush and inductive load against the 0.27 A limit. The AC-15 or general-use inductive load curve for this switch is not separately stated, so the 10 A AC rating should be treated as a resistive or general-use figure; for motor-starter pilot duty, derate accordingly. The switch complies with EN/IEC 60204-1 (machine safety) and EN/IEC 60947-5-1 (control circuit devices), so it meets the standards a panel builder expects for a safety-related position interlock.

UL and CSA approvals are listed, covering North American panel inspections. The Proposition 65 warning (DINP/DIDP) is a California labeling requirement and does not affect the part's functional compliance with UL 508 or CSA C22.2. For European CE marking, the EN/IEC standards cited cover the machinery directive, but the switch itself carries no explicit CE mark in the spec — verify with your compliance team if the end machine requires a CE declaration from the component level.

Wiring and installation constraints

Connection is via a PG13.5 cable gland with screw-clamp terminals inside. The screw-clamp terminal is a field-proven, vibration-resistant termination — no special tooling beyond a screwdriver. The non-plug-in body means the switch is hardwired; there is no quick-disconnect base for swap-out without rewiring. If the panel requires rapid replacement without disturbing the conduit, consider the plug-in variant of this OsiSwitch family. The IP66 rating means the switch withstands high-pressure water jets — suitable for washdown zones in food processing or automotive paint lines. The NEMA 4/12 rating covers indoor use against dust, falling dirt, and non-corrosive liquids.

Frequently asked questions

What are the key electrical ratings for the XCKJ50513?

The contacts are SPDT slow make/break, rated 240 VAC 10 A and 250 VDC 0.27 A. The DC rating is the limiting factor for control circuits — verify your DC load does not exceed 0.27 A at 250 VDC.

What approvals and standards does the XCKJ50513 meet?

It carries UL and CSA approvals. It complies with EN/IEC 60204-1 (safety of machinery) and EN/IEC 60947-5-1 (control circuit devices). The enclosure is rated NEMA 1/2/4/12 and IP66.

What is the UPC for the XCKJ50513?

The UPC is 78590185063.

MPN