Square D XCMD21F2M12 Limit Switch, 240VAC 3A, IP66/IP67

MPNXCMD21F2M12

Square D XCMD21F2M12 general duty limit switch, XCLJ model, 1NO-1NC slow make/break contacts, 240 VAC 3 A / 250 VDC 0.27 A, IP66/IP67 metal enclosure, steel roller plunger actuator, ISO M20 cable gland entry.

$71.59Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

XCMD21F2M12 specifications
ParameterValue
Connection typeISO M20 X 1.5 MM CABLE GLAND/SCREW CLAMP TERMINAL
Actuator (Head type)STEEL ROLLER PLUNGER
Contact configuration1NO-1NC SLOW MAKE/BREAK
EnclosureIP66, IP67
Operating temperature-25 TO 70 DEG C
Body materialMETAL
ModelXCLJ
CategoryGeneral Duty Limit Switches
Pretravel3.2 MM
Sub-CategoryGeneral/Heavy Duty Limit Switch
Total travel5.3 MM
Contact rating240 VAC 3 AMPERE, 250 VDC 0.27 AMPERE
Operating force28 N
Manufacturer brandSquare D Co.
Product descriptionTelemecanique XCLJ567H29 Limit Switch 240Vac 10Amp Xcl +Options
Additional informationAPPLICABLE STANDARD EN/IEC 60204-1, EN/IEC 60947-5-1
Full technical description1NO-1NC Slow Make/Break Contact Configuration; ISO M20 X 1.5 mm Cable Gland/Screw Clamp Terminal Connection Type; 240 VAC 3 Ampere, 250 VDC 0.27 Ampere Contact Rating; IP66, IP67 Enclosure; Metal Body Material; -25 to 70 Deg C Operating Temperature; 28 N Operating Force; Steel Roller Plunger Actuator/Head Type; 3.2 mm Pretravel; 5.3 mm Total Travel; Applicable Standard En/Iec 60204-1, En/Iec 60947-5-1; XCLJ Model
Proposition 65 warningWARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Product details

The XCMD21F2M12: The switch is rated 240 VAC 3 A and 250 VDC 0.27 A. The AC figure covers most 120 V or 240 V control transformer circuits feeding a PLC input or relay coil; the DC rating at 0.27 A is the one to watch when switching DC solenoids or brake coils — exceeding that current at 250 VDC will weld the silver contacts. The 1NO-1NC slow make/break contact block is wired so the NC leg opens before the NO leg closes on actuation. That NC path is the positive-break safety channel per EN/IEC 60947-5-1 — it physically forces the contacts apart even if they weld, so the stop circuit stays open.

Actuator and travel — what the numbers tell the cam designer

The steel roller plunger has 3.2 mm pretravel before the contacts switch, then 5.3 mm total travel. The pretravel is the free movement before the snap point — the cam ramp must cover that distance before the switch changes state. The remaining 2.1 mm is overtravel after switching, which protects the switch body if the cam overdrives. Operating force is 28 N — about 6.3 lbf. That's a medium-force switch: it won't false-trip on machine vibration, but the cam lobe needs enough rise to overcome the spring preload. A low-force cam profile may stall here.

Enclosure and cable entry — washdown readiness

IP66 and IP67 rated metal body. IP66 means dust-tight and protected against powerful water jets; IP67 means it survives immersion up to 1 m for 30 minutes. The cable gland entry is ISO M20 x 1.5 mm — the gland seals around the cable jacket, not the individual conductors, so the cable OD must match the gland range. The metal body sinks heat better than plastic, but the internal contacts and the cable gland seal are the weak points at the extremes — the gland elastomer stiffens below -25 °C.

Lifecycle and sourcing — still a current line item

Compliance documentation covers EN/IEC 60204-1 (machinery electrical safety) and EN/IEC 60947-5-1 (control circuit devices). The Proposition 65 warning for DINP and DIDP is a California labeling requirement, not a material restriction for industrial use.

Frequently asked questions

What is the contact rating at 250 VDC for XCMD21F2M12?

The DC contact rating is 250 VDC at 0.27 A. This is the limiting value for DC loads — switching a solenoid or brake coil above 0.27 A at 250 VDC risks contact welding. The AC rating is 240 VAC at 3 A.

What compliance standards does XCMD21F2M12 meet?

The switch is listed to EN/IEC 60204-1 (safety of machinery — electrical equipment) and EN/IEC 60947-5-1 (control circuit devices and switching elements). It carries the IP66/IP67 enclosure rating and a Proposition 65 warning for California.