Skip to main content
Schneider Electric XS4P18MA230K — Proximity Sensors

Telemecanique XS4P18MA230K Inductive Sensor, 8mm, 2-Wire NO

MPNXS4P18MA230K

Telemecanique OsiSense XS4P18MA230K Inductive Proximity Sensor, 18mm diameter, 8mm sensing distance, 2-wire NO, 24-240 VAC/VDC, IP68, 3-pin micro connector.

$30.48Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

XS4P18MA230K — Sensing
ParameterValue
Sensing distance8 MM
XS4P18MA230K — Output
ParameterValue
Switching frequency25 HZ (AC), 2000 HZ (DC)
Load current5 TO 300 MILLIAMPERE (AC), 5 TO 200 MILLIAMPERE (DC)
XS4P18MA230K — Electrical
ParameterValue
Number of wires2
XS4P18MA230K — Mechanical
ParameterValue
Body materialPPS
XS4P18MA230K — Environmental
ParameterValue
Operating temperature range-13 TO 158 DEG F

Product details

8 mm unshielded sensing in an 18 mm barrel

The XS4P18MA230K is a Telemecanique OsiSense inductive proximity sensor — 18mm threaded barrel, unshielded, with a front sensing distance of 8 mm. It is a 2-wire normally open output rated for 24 to 240 VAC and 24 to 210 VDC, handling up to 300 mA AC or 200 mA DC. Switching frequency reaches 25 Hz on AC and 2000 Hz on DC, so the part works equally well on slower AC proximity applications and faster DC lines. The PPS body and sensing face, combined with IP68 / NEMA 3/4X/6P/12/13 enclosure, give it washdown and outdoor capability. Connection is through a 3-pin 1/2-20 UNF male micro connector.

Sourcing gate: connector vs cable, NO vs NC

Closest functional sibling is XS4P18MB230L1, which shares the same 8 mm sensing distance, voltage range, and current ratings — but differs in two procurement-relevant ways. The MB230L1 terminates in a 5 m PVR cable; the MA230K uses a micro connector. If your panel schema was built for a cabled sensor, the MA230K requires either a mating connector or a pigtail adapter. The second difference is output logic: MA230K is normally open, MB230L1 is normally closed. Verify your PLC input mapping before committing the line to either variant.

The 18 mm threaded barrel fits a standard 18 mm clearance hole; tighten with a 24 mm hex nut. Because the sensor is unshielded, leave an 8 mm air gap around the sensing face when mounting through ferrous metal or the sensor may false-trigger on the surrounding material. The 1/2-20 UNF thread on the micro connector is not the same as an M12×1.0 — double-check your cordsets or order a field-attachable micro-connector with the correct thread. The two wires carry line and load; the third pin is unused in this 2-wire configuration, but the connector shell provides continuity to ground if the panel wiring requires it.

Frequently asked questions

What are the key electrical ratings?

Operating voltage is 24 to 240 VAC and 24 to 210 VDC, load current is 5 to 300 mA AC or 5 to 200 mA DC, and switching frequency is 25 Hz on AC and 2000 Hz on DC.

What compliance approvals does it carry?

UL, CSA, and CE approvals are listed on the sensor.

What is the UPC for this component?

The UPC is 78590184246.

Will XS4P18MA230K drop into a panel specified for XS4P18MB230L1?

No — the MA230K uses a micro connector while the MB230L1 has a fixed 5 m cable, and the output is NO versus NC. Either an adapter cable or rewiring is required.

MPN
XS4P18MA230K