The XSDM600539H7: Rated sensing distance spans 30 to 60 mm from the front face. Operating voltage covers 24 to 210 VDC. Output is a single NO/NC configuration using a 2-wire screw-terminal connection; switching frequency is 10 Hz. Approvals include UL, CSA, and CE — relevant for panel builds that require those marks. Maximum load current is 100 mA, noted alongside the 500 mA headline; the 100 mA figure governs the actual switching capacity.
For buyers filling a BOM line, the 30–60 mm front sensing, 24–210 VDC range, and NO/NC output confirm drop-in fit for legacy Square D sensor positions. No direct form-fit-function replacement is listed, so the original code should be specified.
UL, CSA, and CE approvals are on file. No RoHS or REACH declaration appears in the specification — the California Proposition 65 warning notes the presence of DINP and DIDP. Procurement should verify any additional compliance requirements against their own criteria.