Skip to main content
Schneider Electric XUB0APSNL2 — Photoelectric Sensors

Telemecanique XUB0APSNL2 Photoelectric Sensor, 18mm PNP, IP6

MPNXUB0APSNL2

Telemecanique XUB series, PNP photoelectric sensor, 18mm threaded barrel, 2m PVC cable, 30cm diffuse / 12cm with background suppression / 2m polarized retroreflective / 15m through-beam, 12–24 VDC, IP67.

$36.83Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

XUB0APSNL2 — Identification
ParameterValue
ModelXUB
XUB0APSNL2 — Sensing
ParameterValue
Sensing distance30 CM (DIFFUSE), 12 CM (DIFFUSE WITH BACKGROUND SUPPRESSION), 2 M (POLARIZED RETROREFLECTIVE), 15 M (THROUGH BEAM)
Response time2 MILLISECOND (ON/OFF)
XUB0APSNL2 — Electrical
ParameterValue
Operating voltage range12 TO 24 VDC
XUB0APSNL2 — Connection
ParameterValue
Connection type2 M PVR CABLE
XUB0APSNL2 — Environmental
ParameterValue
EnclosureNEMA 4X/12, IP67
XUB0APSNL2 — Mechanical
ParameterValue
MaterialPLASTIC

Product details

The XUB0APSNL2 is a current-production 18mm threaded photoelectric sensor from the Telemecanique XUB family, with a plastic housing and a 2-meter PVC cable. It outputs PNP (sourcing) and works from 12 to 24 VDC. The sensing ranges cover four common modes: 30 cm diffuse, 12 cm with background suppression, 2 m polarized retroreflective, and 15 m through-beam — all using the same unit via the light/dark operating mode selection. Response is 2 milliseconds on/off, switching at 250 Hz, so it keeps up with fast-moving parts on a conveyor or packaging machine.

Signal integrity in a noisy plant

The 2-meter cable is unshielded PVC — fine for runs away from VFDs and welders. If you're mounting near a variable-frequency drive or high-current bus, run the cable in a separate metal conduit, or switch to a shielded version. The sensor itself switches clean at 250 Hz, but noise on the output can false-trigger a PLC input. Check the shield ground first if you see spurious counts. The 100 mA max load is plenty for a PLC input or a small relay, but don't drive a solenoid directly.

Frequently asked questions

What is the closest functional second-source if I have XUB0BNSNL2 on the BOM?

The XUB0BNSNL2 is the NPN (sinking) version with a metal housing. Functionally it has the same sensing distances, response time, and voltage range, but the output polarity differs. They are not drop-in interchangeable without rewiring the load side. For PNP systems, the XUB0BPSNL2 (metal, PNP) is a closer form/fit match except for housing material.

What is the UPC for the XUB0APSNL2?

The UPC is 78590179172.

Will the XUB0APSNL2 drop into a panel that was specified around XUB0BNSNL2 without rewiring?

No. The XUB0APSNL2 is PNP (sourcing) while XUB0BNSNL2 is NPN (sinking). The physical mount and cable are identical, but the output wiring must change to match the PLC or load input type. Check the input card sinking/sourcing compatibility before swapping.

MPN
XUB0APSNL2