Skip to main content
Schneider Electric XUB2APBWM12R — Photoelectric Sensors

Telemecanique XUB2APBWM12R Photoelectric Sensor, 15 m Throug

MPNXUB2APBWM12R

Telemecanique XUB series tubular photoelectric through-beam sensor, XUB2APBWM12R, PBT housing, 15 m sensing distance, PNP NC output, 12-24 VDC, M12 4-pin connector, IP67.

$63.59 – $68.59Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

XUB2APBWM12R — Identification
ParameterValue
ModelXUB
XUB2APBWM12R — Sensing
ParameterValue
Sensing distance15 M
Response time1 MILLISECOND (ON/OFF)
XUB2APBWM12R — Electrical
ParameterValue
Operating voltage range12 TO 24 VDC
XUB2APBWM12R — Connection
ParameterValue
Connection typeM12 4 PIN DC MICRO MALE CONNECTOR
XUB2APBWM12R — Environmental
ParameterValue
EnclosureNEMA 4X/12, IP65, IP67
XUB2APBWM12R — Mechanical
ParameterValue
MaterialPBT

Product details

The Telemecanique XUB2APBWM12R is a tubular photoelectric through-beam detector from the XUB series, built for presence sensing across a 15 m gap. It operates on 12 to 24 VDC with a PNP normally-closed output, switching at 500 Hz and responding in 1 ms on/off. The housing is threaded PBT rated NEMA 4X/12 and IP65/IP67, with a 90-degree side sensing position and an M12 4-pin DC micro male connector.

The 15 m sensing distance is the key spec for a through-beam pair — it defines the maximum separation between emitter and receiver, not a detection window. The 1 ms response time suits high-speed counting or registration applications, while the 500 Hz switching frequency confirms it can keep up with fast-moving targets. The PNP NC output is a sourcing (positive-switching) configuration that pulls the load high when the beam is unbroken; verify your PLC input card expects PNP logic before wiring. The M12 4-pin connector is standard for industrial sensors, but note the 90-degree side exit — plan cable routing accordingly if the panel layout expects a straight axial connector.

Integration Notes

Threaded 18 mm barrel with included mounting nut — installs through a standard 18 mm hole or bracket. The M12 male connector mates with a standard 4-pin female cordset; wire per the PNP NC pinout (pin assignments vary by cordset, confirm with the datasheet). The 3-wire configuration (V+, V-, output) is straightforward. The side-sensing head means the optical axis is perpendicular to the barrel axis — align the emitter and receiver so their side windows face each other across the 15 m gap.

Frequently asked questions

What is the UPC for XUB2APBWM12R?

The listed UPC is 78590151213.

Will XUB2APBWM12R drop into a panel specified around XUAH0224S without rewiring?

No. XUAH0224S uses an M8 3-pin connector; XUB2APBWM12R uses an M12 4-pin connector. The connector and cable are different, so rewiring or a different cordset is required. Additionally, the XUAH0224S has a 2 m range versus 15 m, so the application distance must match.

What compliance documentation does XUB2APBWM12R carry?

The sensor carries UL, CSA, and CE approvals as listed in the specifications. A Proposition 65 warning for California is also noted for the materials DINP and DIDP.

MPN