Skip to main content
Siemens 3RH1131-2AP00 — Contactors

Siemens 3RH1131-2AP00 SIRIUS Auxiliary Contactor, 3 NO, S00

MPN3RH1131-2AP00

Siemens SIRIUS auxiliary contactor, 3RH1131-2AP00, 3 NO contacts, S00 frame size, 10 A AC-12, screw and snap-on mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RH1131-2AP00 — Identification
ParameterValue
Contactor frame sizeS00
3RH1131-2AP00 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1131-2AP00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RH1131-2AP00 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1131-2AP00 — Protection & Coordination
ParameterValue
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RH1131-2AP00 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
3RH1131-2AP00 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1131-2AP00 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
3RH1131-2AP00 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

It carries three normally-open instantaneous contacts, each rated 10 A in AC-12 duty, which is the resistive-load category per IEC 60947-5-1. That 10 A figure governs the maximum continuous current through the contacts when switching resistive loads like indicator lamps or PLC inputs; for inductive loads (contactors, solenoids), the make/break capability drops and you'd refer to the AC-15 or DC-13 values. The S00 frame size tells you this auxiliary contactor mates physically with S00 power contactors in the SIRIUS family — it shares the same 45 mm width and snap-on or screw-mount footprint, so it clips directly onto the contactor or onto DIN rail alongside it. Electrical endurance will be lower and depends on the switched load and frequency.

Mounting and wiring integration

The screw terminals accept 2x 0.25 to 2.5 mm² solid or stranded wire — that's the range for the power circuit terminals; auxiliary wiring typically uses 1.5 mm² control cable. Strip length and torque are per the datasheet, but the 0.25 mm² lower bound means fine signal wiring is accommodated without adapters. Depth is 73 mm, which is the dimension from the DIN rail mounting surface to the front of the terminals. That's a standard depth for S00 auxiliary blocks; verify clearance against the enclosure door or gland plate if the panel is tight on depth. Side clearance to adjacent devices is 0 mm — it can be mounted flush side-by-side with other SIRIUS devices without derating, which is typical for auxiliary contactors that don't generate significant heat.

Frequently asked questions

What is the closest functional second-source to the 3RH1131-2AP00?

The 3RT1017-1AP01 is a peer SIRIUS contactor in the same S00 frame, but it is a power contactor with a coil, not an auxiliary contactor block. The 3RH1131-2AP00 is the dedicated auxiliary contactor; if you need the same 3 NO contact configuration on an S00 frame, this is the direct part. A 3RT power contactor with an auxiliary block added would not be a drop-in replacement without rewiring the coil circuit.

MPN
3RH1131-2AP00