Siemens SIRIUS, motor protection circuit breaker, 3RV2011-0AA40, CLASS 10, 100 kA at 400 V, size S00, screw and snap-on 35 mm DIN rail mount.

StockOut of Stock
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0AA40 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0AA40 — Electrical
ParameterValue
Rated operational current (Ie)0.16 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV2011-0AA40 — Protection & Tripping
ParameterValue
Overload release setting range0.11 ... 0.16 A
Instantaneous short-circuit trip current2.1 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0AA40 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0AA40 — Connections
ParameterValue
Main-circuit terminal typeRing cable lug connection
Main-circuit connector arrangementTop and bottom

Mechanical

3RV2011-0AA40 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0AA40 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0AA40 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Siemens 3RV2011-0AA40 SIRIUS Motor Protection Circuit Breaker

The Siemens 3RV2011-0AA40 is a SIRIUS motor protection circuit breaker designed to protect motors against overload and short-circuit, with a CLASS 10 trip characteristic that matches standard motor starting curves — it holds through the inrush and trips before the winding heats past rated temperature. Rated for a short-circuit breaking capacity of 100 kA at 400 V AC, this breaker can safely interrupt high-fault currents without cascading upstream, making it suitable for panels with high available fault current. It includes phase failure detection, so a lost phase on the line side will cause the breaker to trip — a common failure mode that can single-phase a motor and burn it out quickly.

Mounting and Panel Integration

Fastens via screw and snap-on mounting onto 35 mm DIN rail per DIN EN 60715, which is the standard rail profile in most industrial control panels. Size S00 means it fits the compact footprint — 45 mm wide, 97 mm deep, 97 mm tall — leaving room for adjacent devices on the same rail. Mounting position is any, so it can be laid flat or stood vertical without derating. Clearance requirements: 50 mm above and below, 30 mm at the sides, zero forward or backward — this keeps heat dissipation paths open and allows the arc chute to vent.

Environmental and Operating Range

Rated for operation from -20 to +60 °C, which covers most indoor panel environments including unventilated enclosures near process heat. Storage and transport range extends from -50 to +80 °C.

Frequently asked questions

What is the short-circuit breaking capacity of the 3RV2011-0AA40?

It is rated 100 kA at 400 V AC, which means it can safely clear a fault current up to 100,000 amps at that voltage without failing.

What does CLASS 10 trip mean for motor protection?

CLASS 10 means the breaker will trip within 10 seconds at 7.2× the thermal setting, which is fast enough to protect standard induction motors during locked-rotor conditions but allows normal starting inrush.

Where can I buy the 3RV2011-0AA40 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Does the 3RV2011-0AA40 include phase failure protection?

Yes, it has phase failure detection built in, so it will trip if one phase is lost, preventing single-phase motor damage.