Siemens 3RV2011-0EA15-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0EA15-ZX95 SIRIUS Motor Protection CB, Class

MPN3RV2011-0EA15-ZX95
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-0EA15-ZX95, Class 10 trip, 100 kA breaking capacity at 400 V AC, screw terminals, 45 mm wide.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0EA15-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0EA15-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)0.4 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV2011-0EA15-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range0.28 ... 0.4 A
Instantaneous short-circuit trip current5.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0EA15-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0EA15-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12

Mechanical

3RV2011-0EA15-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0EA15-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0EA15-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

SIRIUS motor protection circuit breaker, Class 10, 100 kA

The Siemens 3RV2011-0EA15-ZX95 is a SIRIUS motor protection circuit breaker designed for motor protection, with a Class 10 trip characteristic. It delivers a 100 kA breaking capacity at 400 V AC, meaning it can safely interrupt fault currents up to that level without cascading upstream — critical for panel SCCR compliance in industrial distribution. The unit mounts via screw and snap-on onto a 35 mm standard mounting rail per DIN EN 60715, fitting into any standard control panel enclosure. At 45 mm wide and 97 mm deep, it occupies a single modular slot, leaving room for adjacent contactors or overloads in a motor starter lineup. Phase failure detection is built in, so the breaker trips on loss of a phase — a common cause of motor burnout in three-phase systems. Ground fault detection is not included, so that function must be handled separately if required.

Integration and wiring

Screw-type terminals on the main current circuit accept 2x (0.5... 1.5 mm²) or 2x (0.75... 2.5 mm²) solid or stranded conductors. The auxiliary contact block handles 1 A at 24 V, 0.5 A at 120/125/230 V, and 0.15 A at 60 V — check your control voltage against these ratings for signal compatibility. Mounting position is any, giving flexibility in tight panels. Required clearances: 50 mm upwards and downwards, 30 mm at the side for heat dissipation and arc flash containment. Operating temperature range is -20 to +60 °C with temperature compensation active across that span, so the trip curve stays accurate in warm cabinets near drives or transformers.

Frequently asked questions

Where can I buy 3RV2011-0EA15-ZX95?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3RV2011-0EA15-ZX95 at 400 V?

It is rated at 100 kA at 400 V AC, which is a high-interrupting capacity suitable for industrial main distribution panels.

What trip class is 3RV2011-0EA15-ZX95?

It is a Class 10 trip, meaning it will trip within 10 seconds at 7.2x the thermal setting — standard for protecting standard induction motors during startup.

MPN
3RV2011-0EA15-ZX95