Siemens 3RV2011-0FA10-ZW97 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0FA10-ZW97 SIRIUS Motor Protection Circuit B

MPN3RV2011-0FA10-ZW97
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-0FA10-ZW97, Size S00, Trip Class 10, 100 kA SCCR at 400 V AC, screw-type terminals, 45 mm wide, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0FA10-ZW97 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0FA10-ZW97 — Electrical
ParameterValue
Rated operational current (Ie)0.5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV2011-0FA10-ZW97 — Protection & Tripping
ParameterValue
Overload release setting range0.35 ... 0.5 A
Instantaneous short-circuit trip current6.5 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0FA10-ZW97 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0FA10-ZW97 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV2011-0FA10-ZW97 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0FA10-ZW97 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0FA10-ZW97 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

What this breaker is and where it lands

The Siemens SIRIUS 3RV2011-0FA10-ZW97 is a motor protection circuit breaker in Size S00 — the compact frame of the SIRIUS family, designed to snap onto a 35 mm DIN rail per DIN EN 60715 and fit into a control panel with a 45 mm width footprint. Rated for motor starting duty with Trip Class 10, it provides phase failure detection and a 100 kA short-circuit breaking capacity at 400 V AC — high enough to coordinate with most downstream contactors without cascading upstream. The operating temperature range of -20 to +60 °C covers most indoor panel environments, and the rated voltage span of 20 to 690 V means it handles everything from 24 V control circuits up to 690 V line feeds.

Clearance and mounting — what the numbers mean for panel layout

The breaker needs 50 mm clearance upward and downward, 30 mm to the side, and zero forward or backward — so you can pack it tight against the backplane or a busbar cover as long as the vertical breathing space is respected. Screw-type terminals on the main circuit accept 2x (0.75 to 2.5 mm²) solid or stranded, or 2x 4 mm² — enough for the motor branch circuit wiring typical of a Size S00 breaker.

Frequently asked questions

What is the closest functional second-source for 3RV2011-0FA10-ZW97?

The 3RV2011-0AA10 is a Size S00 motor protection breaker from the same SIRIUS family, but it carries different trip settings and auxiliary configurations — verify the overload range and terminal layout before substituting into an existing panel.

What is the SCCR of 3RV2011-0FA10-ZW97 at 400 V?

100 kA at 400 V AC, which is the same rating at 240 V, 500 V, and 690 V — a flat 100 kA across the common industrial voltages.

Will 3RV2011-0FA10-ZW97 drop into a panel specified for 3RV2011-0AA10 without rewiring?

Both are Size S00 with the same 45 mm width and DIN rail mounting, so the mechanical fit is identical. The terminal layout and screw-type connections are the same, but the trip class and phase failure detection differ — the -0FA10 variant includes phase failure detection and Trip Class 10, which the -0AA10 may not share.

Where can I buy 3RV2011-0FA10-ZW97?

Sourced and quoted to order through independent distribution against an RFQ. Availability and current pricing are confirmed at quote time.