Siemens 3RV2011-0FA20-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens SIRIUS 3RV2011-0FA20-ZX95 Motor Protection Circuit B

MPN3RV2011-0FA20-ZX95
Active

Siemens SIRIUS 3RV2011-0FA20-ZX95, motor protection circuit breaker, size S00, CLASS 10, 100 kA breaking capacity at 400 V AC, screw and snap-on mounting on 35 mm DIN rail.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0FA20-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0FA20-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)0.5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W

Protection & Tripping

3RV2011-0FA20-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range0.35 ... 0.5 A
Instantaneous short-circuit trip current6.5 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0FA20-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0FA20-ZX95 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)

Mechanical

3RV2011-0FA20-ZX95 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0FA20-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0FA20-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

What it is and what it does

The Siemens SIRIUS 3RV2011-0FA20-ZX95 is a motor protection circuit breaker in the S00 frame size, designed to protect motor branches against overload and short-circuit in a single device. It is rated for CLASS 10 trip characteristics, which means it disconnects within 10 seconds at 7.2× the thermal setting — fast enough to protect a standard induction motor winding before insulation damage sets in. The breaker carries a 100 kA breaking capacity at 400 V AC, making it suitable for installation at the motor branch where fault current levels can be high. Phase failure detection is built in, so a lost phase on the line side trips the breaker — no separate phase-loss relay needed.

Mounting and panel fit

Mounts via screw or snap-on onto a 35 mm DIN rail per DIN EN 60715. The S00 footprint is compact: 45 mm wide, 97 mm deep, 106 mm tall. Clearance requirements are 50 mm above and below, 30 mm to the side, and zero forward or backward — so a panel layout with 50 mm wireway above and below the rail is sufficient.

Frequently asked questions

What is the breaking capacity of this circuit breaker?

It is rated for 100 kA at 240 V AC, 400 V AC, 500 V AC, and 690 V AC, covering most industrial distribution fault levels.

Will 3RV2011-0FA20-ZX95 drop into a panel specified for 3RV2011-0BA20?

Both are S00 frame size, same mounting pattern and DIN rail clip, so the physical fit is identical. The difference is in the internal trip setting range and accessory compatibility — verify the overload setting matches the motor FLA before swapping.

Where can I buy 3RV2011-0FA20-ZX95 and how is it quoted?

It is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.