Siemens 3RV2011-0GA10 — Motor Protection Circuit Breakers (MPCB)

Siemens SIRIUS 3RV2011-0GA10 Motor Protection Circuit Breake

MPN3RV2011-0GA10
Active

Siemens SIRIUS 3RV2011-0GA10 motor protection circuit breaker, size S00, 45 mm wide, 100 kA breaking capacity at 400 V AC, Trip Class 10, screw terminals, snap-on DIN rail mount.

$83.57 – $152.38Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-0GA10 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-0GA10 — Electrical
ParameterValue
Rated operational current (Ie)0.63 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)5.5 W
Power loss, per pole (AC, hot)1.8 W
3RV2011-0GA10 — Protection & Tripping
ParameterValue
Overload release setting range0.45 ... 0.63 A
Instantaneous short-circuit trip current8.2 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-0GA10 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-0GA10 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12
3RV2011-0GA10 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-0GA10 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-0GA10 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

It's designed to protect motor branch circuits against overload, short circuit, and phase failure — the three faults that take out a motor on a conveyor zone or pump station. Breaking capacity is 100 kA at 400 V AC and 500 V AC, and the same 100 kA at 690 V AC.

The 45 mm width is the S00 standard — one 45 mm slot on the rail. Any mounting position is allowed, which helps when you're packing breakers into a tight enclosure. Clearance requirements: 50 mm above and below, 30 mm to the sides, 0 mm forward and backward. That's the space you need for arc quenching and terminal access — plan for it in the gland plate layout. Terminals are M3 screw-type for the main circuit, accepting 2× (0.75 to 2.5 mm²) or 2× 4 mm² solid or stranded. Screwdriver shaft diameter 5 to 6 mm — a standard Pozidriv #2 or flathead will fit.

Environmental and lifecycle

The storage range is wider because the breaker isn't carrying current — it's the thermal-magnetic trip elements that limit the operating range, not the housing. Lifecycle status is current production. It's a line item you can quote to order against an RFQ without worrying about obsolescence.

Frequently asked questions

What are the key dimensions for panel layout?

Width is 45 mm, depth is 97 mm, height is 97 mm. Clearance: 50 mm above and below, 30 mm to the sides, 0 mm forward and backward.

What breaking capacity does it have at 400 V?

100 kA at 400 V AC, and the same 100 kA at 500 V AC and 690 V AC. That's a high interrupting rating for a size S00 breaker.

Does it detect phase failure?

Yes, phase failure detection is built in. It will trip if one phase is lost, protecting the motor from single-phasing.

What trip class is it?

Trip Class 10, meaning it trips within 10 seconds at 7.2× the thermal setting. This is standard for protecting standard induction motors during starting.

MPN
3RV2011-0GA10