Siemens 3RV2011-0HA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0HA10-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2011-0HA10-ZX95
Active

Siemens SIRIUS, motor protection circuit breaker, size S00, Trip Class 10, 100 kA breaking capacity at 400 V, phase failure detection, screw-type terminals, 3RV2011-0HA10-ZX95.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0HA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0HA10-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)0.8 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2011-0HA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range0.55 ... 0.8 A
Instantaneous short-circuit trip current10 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0HA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0HA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12

Mechanical

3RV2011-0HA10-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0HA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0HA10-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Mounting and integration

The 3RV2011-0HA10-ZX95: Mounts via screw fixing or snap-on onto a 35 mm DIN rail per DIN EN 60715. The 45 mm width and 97 mm depth fit standard S00 panel layouts. Any mounting position is allowed, and the operating temperature range of -20 to +60 °C covers most indoor panel environments. Terminal capacity accepts 2x (0.75 to 2.5 mm²) solid or stranded, or 2x 4 mm², with M3 screw terminals for the main current circuit.

Frequently asked questions

What is the breaking capacity of 3RV2011-0HA10-ZX95 at 400 V?

It has a 100 kA breaking capacity at 400 V AC, which means it can safely interrupt fault currents up to that level without upstream devices needing to clear the fault.

What is the Trip Class of this circuit breaker?

It is Trip Class 10, meaning it will trip within 10 seconds at 600% of the thermal setting, protecting the motor during start-up.

Does 3RV2011-0HA10-ZX95 detect phase failure?

Yes, it includes phase failure detection, which prevents single-phasing damage to the motor.

How do I get pricing and availability for 3RV2011-0HA10-ZX95?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Submit an RFQ to confirm current pricing and availability.