Siemens 3RV2011-0JA10-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0JA10-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV2011-0JA10-ZW96
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-0JA10-ZW96, Class 10 trip, 100 kA SCCR at 400 V, 45 mm wide, screw and snap-on DIN-rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0JA10-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0JA10-ZW96 — Electrical
ParameterValue
Rated operational current (Ie)1 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2011-0JA10-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range0.7 ... 1 A
Instantaneous short-circuit trip current13 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0JA10-ZW96 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0JA10-ZW96 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV2011-0JA10-ZW96 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0JA10-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0JA10-ZW96 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

What it is and what it does

The Siemens SIRIUS 3RV2011-0JA10-ZW96 is a motor protection circuit breaker designed to protect induction motors against overload and short-circuit faults. It integrates a Class 10 trip characteristic, meaning it will trip within 10 seconds at 7.2× the thermal setting — fast enough to protect standard squirrel-cage motors during locked-rotor conditions. The breaker also includes phase failure detection, which prevents single-phasing damage on a three-phase motor.

Breaking capacity and coordination

Rated short-circuit breaking capacity hits 100 kA at 400 V AC and holds the same figure at 500 V and 690 V AC. That is a Type 2 coordination rating — the breaker clears a bolted fault without welding its own contacts or damaging the upstream contactor, assuming the manufacturer's coordination tables are followed. The 100 kA figure holds across the full 400–690 V range, which is unusual for a 45 mm-wide device; most compact breakers derate above 480 V.

Mounting and panel fit

Mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715. The 45 mm width and 97 mm depth mean it occupies a single 45 mm module on the rail — no extra side clearance needed for the actuator mechanism. Clearance requirements: 50 mm above and below, zero forward or backward, and 30 mm to the side. Any mounting position is permitted.

Lifecycle and sourcing posture

The lifecycle stage is recorded as current production. No phase-out notice or last-time-buy date is on record. The part is sourced and quoted to order through independent distribution; availability and current pricing are confirmed at quote time against an RFQ.

MPN