Siemens 3RV2011-0JA20-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-0JA20-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2011-0JA20-ZX95
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-0JA20-ZX95, Class 10 trip, 100 kA breaking capacity at 400 V AC, 45 mm wide, screw and snap-on DIN rail mounting.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-0JA20-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-0JA20-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)1 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2011-0JA20-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range0.7 ... 1 A
Instantaneous short-circuit trip current13 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-0JA20-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-0JA20-ZX95 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)

Mechanical

3RV2011-0JA20-ZX95 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-0JA20-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-0JA20-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens SIRIUS 3RV2011-0JA20-ZX95 is a motor protection circuit breaker designed for protecting induction motors against overload, short circuit, and phase failure. Its 100 kA breaking capacity at 400 V AC means it can safely interrupt a fault current up to that level without upstream fuses needing to coordinate — a real advantage in high-fault panels where you want to keep the main breaker in. Trip Class 10 gives you a 10-second maximum trip time at 7.2× rated current, which is the standard for standard-duty motor starts (pumps, fans, compressors).

Mounting and integration

Mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715. The 45 mm width and 97 mm depth mean it fits standard DIN-rail enclosures without overhang — plan for 50 mm clearance above and below and 30 mm at the sides for airflow and wiring access. Spring-loaded terminals on the main circuit accept 2×(0.5–4 mm²) solid or stranded, so no lug crimping needed for motor leads up to 4 mm².

Frequently asked questions

Who supplies 3RV2011-0JA20-ZX95 and how is it quoted for volume purchases?

We supply it through independent distribution channels. Submit an RFQ for volume pricing and current availability — confirmed at quote time.

Will 3RV2011-0JA20-ZX95 drop into a panel specified around 3RV2011-0BA20 without rewiring?

Both share the same 45 mm width and DIN-rail mounting, so the footprint matches. The -0JA20-ZX95 uses spring-loaded terminals; the -0BA20 may use screw terminals. Check your panel's terminal type before swapping — if it's wired for screw terminals, you may need to adapt the wiring method.

What is 3RV2011-0JA20-ZX95's listed depth?

The depth is 97 mm, which fits standard DIN-rail enclosures without overhang.

What is 3RV2011-0JA20-ZX95's listed width?

The width is 45 mm, a standard single-module width for this class of motor protection breaker.