Skip to main content
Siemens 3RV2011-1AA10-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1AA10-ZX95 SIRIUS Motor Protection CB, 100 k

MPN3RV2011-1AA10-ZX95
Active

Siemens SIRIUS 3RV2011-1AA10-ZX95 motor protection circuit breaker, 100 kA SCCR at 400 V, Trip Class 10, screw/snap-on DIN rail mounting.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-1AA10-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-1AA10-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)1.6 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2011-1AA10-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range1.1 ... 1.6 A
Instantaneous short-circuit trip current21 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)100 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V100 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-1AA10-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-1AA10-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (18 ... 14), 2x 12

Mechanical

3RV2011-1AA10-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-1AA10-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-1AA10-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker, 100 kA SCCR

The Siemens SIRIUS 3RV2011-1AA10-ZX95 is a motor protection circuit breaker rated for 100 kA short-circuit breaking capacity at 400 V AC — that means it can safely interrupt a fault current up to 100,000 A without upstream fuses needing to clear first. Trip Class 10 means it will trip within 10 seconds at 7.2× rated current, which is standard for protecting standard induction motors during start-up without nuisance tripping on the inrush. Mounts on 35 mm DIN rail (DIN EN 60715) with either screw or snap-on fastening, so it drops into any standard panel without extra brackets. 45 mm wide — fits the standard 45 mm module width, leaving room for contactors and overloads in the same row.

Sourcing & lifecycle

Current production. This is the standard catalog part, not a phase-out or NRND line item. Available to quote against an RFQ through independent distribution channels — no long lead-time risk for a BOM freeze.

Mounting & integration

Screw-type terminals for the main circuit accept 2× 0.75–2.5 mm² solid/stranded or 2× 4 mm² per terminal. Mounting position any — horizontal or vertical in the panel, no derating needed for orientation. Clearance: 50 mm above/below, 30 mm to the side, zero forward/backward. Ambient range -20 to +60 °C operating, storage -50 to +80 °C.

Frequently asked questions

Where can I buy 3RV2011-1AA10-ZX95?

Sourced to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — no stock count or lead-time number is published here.

What are the key ratings of 3RV2011-1AA10-ZX95?

100 kA SCCR at 400 V AC, Trip Class 10, 45 mm wide, screw/snap-on DIN rail mount.

MPN
3RV2011-1AA10-ZX95