Skip to main content
Siemens 3RV2011-1BA20 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1BA20 SIRIUS Motor Protection Circuit Breake

MPN3RV2011-1BA20
Active

Siemens SIRIUS 3RV2011-1BA20 motor protection circuit breaker, Trip Class 10, spring-loaded terminals, screw and snap-on mounting onto 35 mm DIN rail, 45 mm width, 97 mm depth.

$31.14Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-1BA20 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1BA20 — Electrical
ParameterValue
Rated operational current (Ie)2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-1BA20 — Protection & Tripping
ParameterValue
Overload release setting range1.4 ... 2 A
Instantaneous short-circuit trip current26 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)10 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V10 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1BA20 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1BA20 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)
Conductor range, AWG (main contacts)2x (20 ... 12)
3RV2011-1BA20 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-1BA20 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1BA20 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens 3RV2011-1BA20 is a SIRIUS motor protection circuit breaker designed for Class 10 trip response, meaning it will disconnect the motor within 10 seconds under a locked-rotor condition — a standard fit for general-purpose induction motors driving pumps, fans, and conveyors. It mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715, in any position, and occupies 45 mm of panel width with a 97 mm depth — a compact footprint that leaves room for contactors and overload relays on the same rail. The main circuit connection uses spring-loaded terminals accepting 2x (0.5 to 4 mm²) solid or stranded wire, which speeds panel wiring and maintains consistent clamping force over time compared to screw terminals.

Breaking Capacity and Short-Circuit Coordination

Rated breaking capacity reaches 100 kA at 240 V, 400 V, and 500 V AC, dropping to 10 kA at 690 V AC. This 100 kA figure at common distribution voltages (400 V) means the breaker can safely interrupt high-fault-current scenarios without upstream fuses or a larger frame — a key advantage in high-capacity MCCs or transformer-fed panels where available fault current exceeds 50 kA. For backup fuse coordination, the unit is rated for gL/gG fuses: 25 A at 400 V and 500 V, 20 A at 690 V. This lets the designer size the upstream fuse to match the breaker's let-through energy without over-fusing the branch.

Integration and Mounting Notes

Clearance requirements: 50 mm upwards and downwards, 30 mm to the side, 0 mm forwards and backwards — so the breaker can sit flush against a panel backplate or enclosure wall without additional standoffs. Ambient operating range is -20 to +60 °C; storage and transport range extends to -50 to +80 °C.

Frequently asked questions

What is the closest functional alternative to the 3RV2011-1BA20?

The 3RV1011-1HA10 is a similar SIRIUS motor protection circuit breaker in the same Trip Class 10 and 45 mm width, but it uses screw terminals instead of spring-loaded terminals and has a different breaking capacity curve. The 3RV1011-0GA10 is a narrower (45 mm) variant with lower breaking capacity. Neither is a drop-in replacement without verifying the short-circuit rating and terminal type against your BOM.

Where can I buy the 3RV2011-1BA20 and how is it quoted?

Sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time. Insist on factory-original packaging with date codes and lot traceability to maintain chain of custody.

Will the 3RV2011-1BA20 drop into a panel specified around the 3RV1011-0GA10?

The 3RV2011-1BA20 shares the same 45 mm width, 97 mm depth, and DIN-rail mounting footprint as the 3RV1011-0GA10, so it will physically fit the same rail position. However, the 3RV2011-1BA20 uses spring-loaded terminals while the 3RV1011-0GA10 uses screw terminals — verify that your wiring lugs and ferrule sizes (0.5 to 4 mm²) are compatible before swapping.

MPN
3RV2011-1BA20