Siemens 3RV2011-1CA15-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1CA15-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2011-1CA15-ZX95
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-1CA15-ZX95, Class 10 trip, 100 kA breaking capacity at 400 V, phase failure detection, screw and snap-on 35 mm DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-1CA15-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-1CA15-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)2.5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2011-1CA15-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range1.8 ... 2.5 A
Instantaneous short-circuit trip current33 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)10 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V10 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-1CA15-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-1CA15-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)

Mechanical

3RV2011-1CA15-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-1CA15-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-1CA15-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The Siemens SIRIUS 3RV2011-1CA15-ZX95 is a motor protection circuit breaker designed for Class 10 trip characteristics, meaning it will trip within 10 seconds at 7.2× the thermal setting — standard for protecting standard induction motors during start-up. It offers a 100 kA breaking capacity at 400 V, so it can safely interrupt high fault currents without upstream fuses in most panel applications. Phase failure detection is built in, which prevents single-phasing damage on three-phase motor loads. Mounting is via screw or snap-on onto 35 mm DIN rail per DIN EN 60715, and the unit fits any orientation.

Breaking capacity and selectivity

The 100 kA rated short-circuit breaking capacity at 400 V (Icu per IEC 60947-2) means this breaker can clear faults up to that level without needing a backup fuse. At 690 V the rating drops to 10 kA — still adequate for most 690 V motor circuits, but verify coordination with upstream protective devices if the available fault current exceeds that. The gL/gG fuse ratings for the main contacts are 25 A up to 500 V, and 20 A at 690 V, giving a clear selectivity window.

Integration and wiring

The 45 mm width fits standard 45 mm wide DIN-rail slots, matching the footprint of the SIRIUS 3RV2 series. Main contact terminals accept 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid or stranded wire, with M3 screw terminals. Auxiliary contact ratings: 1 A at 24 V, 0.5 A at 120/125/230 V, 0.15 A at 60 V — enough for PLC inputs or contactor coils within those limits. Ambient operation range is -20 to +60 °C; storage and transport range is -50 to +80 °C. Minimum clearance: 50 mm above and below, 30 mm to the side, zero forward/backward.

Frequently asked questions

Where can I buy 3RV2011-1CA15-ZX95 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

Will 3RV2011-1CA15-ZX95 drop into a panel specified around 3RV2021-1FA15 without rewiring?

Both are 45 mm wide SIRIUS motor protection breakers with the same DIN-rail mounting and M3 screw terminals, so mechanical fit and wiring are identical. The 3RV2021-1FA15 is a higher-current variant; verify the thermal setting range matches your motor FLA before substituting.

What compliance documentation does this brand provide for 3RV2011-1CA15-ZX95?

As a Siemens SIRIUS product, it carries CE marking per the Low Voltage Directive and is designed to IEC 60947-2 and IEC 60947-4-1. RoHS and REACH declarations are available from Siemens documentation. The evidence does not list UL or CSA marks specifically for this order code.

MPN
3RV2011-1CA15-ZX95