Skip to main content
Siemens 3RV2011-1CA20-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1CA20-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2011-1CA20-ZX95
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-1CA20-ZX95, CLASS 10 trip, 45 mm wide, screw and snap-on mounting onto 35 mm DIN rail, spring-loaded terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-1CA20-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1CA20-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)2.5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-1CA20-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range1.8 ... 2.5 A
Instantaneous short-circuit trip current33 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)10 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V10 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1CA20-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1CA20-ZX95 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)
3RV2011-1CA20-ZX95 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-1CA20-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1CA20-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Rated breaking capacity hits 100 kA at 240 V, 400 V, and 500 V, dropping to 10 kA at 690 V. The gL/gG fuse coordination values are 25 A at 400 V and 500 V, 20 A at 690 V, so if you do back it with fuses for a higher SCCR, those are the maximum ratings.

Width is 45 mm, depth 97 mm, height 106 mm — that's a single 45 mm module on the DIN rail, leaving room alongside contactors or overloads. Mounting position any, so vertical or horizontal panel layouts work.

Frequently asked questions

Where can I buy 3RV2011-1CA20-ZX95 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing.

What is the breaking capacity of 3RV2011-1CA20-ZX95 at 400 V?

100 kA at 400 V rated value, which means it can interrupt a high-fault bolted short without upstream fuses needing to clear.

What is the trip class of 3RV2011-1CA20-ZX95?

CLASS 10 — it trips within 10 seconds at 7.2× rated current, matching standard motor starting curves for most induction motors.

Does 3RV2011-1CA20-ZX95 have phase failure detection?

Yes, phase failure detection is built in — a lost phase trips the breaker before the motor single-phases.

MPN