Skip to main content
Siemens 3RV2011-1DA15-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1DA15-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2011-1DA15-ZX95
Active

Siemens SIRIUS 3RV2011-1DA15-ZX95 motor protection circuit breaker, Class 10, 100 kA SCCR at 400 V, phase failure detection, screw and snap-on 35 mm DIN rail mount, 45 mm wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-1DA15-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1DA15-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)3.2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W
3RV2011-1DA15-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range2.2 ... 3.2 A
Instantaneous short-circuit trip current42 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)10 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V10 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1DA15-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1DA15-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV2011-1DA15-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-1DA15-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1DA15-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Motor protection circuit breaker, SIRIUS series

Rated for a supply voltage range of 20 to 690 V, it carries a 100 kA short-circuit breaking capacity at 240 V, 400 V, and 500 V, dropping to 10 kA at 690 V. The fuse backup ratings are specified: gL/gG 25 A at 400 V and 690 V, gL/gG 32 A at 500 V.

The 45 mm width (three 15 mm modules) fits standard panel layout grids. Any mounting position is permitted, with minimum clearances of 50 mm upward and downward, 30 mm to the side, and zero forward/backward clearance required. Terminal capacity accepts 2× (0.5 to 1.5 mm²) or 2× (0.75 to 2.5 mm²) solid or stranded wire; main contact screws are M3.

Frequently asked questions

What is the closest functional second-source for 3RV2011-1DA15-ZX95?

The 3RV1011-0GA10 and 3RV1011-1HA10 are the closest peers in the SIRIUS 3RV10 series. The 3RV2011-1DA15-ZX95 is a 3RV2 generation device; the 3RV10 series shares the same form factor and DIN rail footprint, but verify the specific thermal setting range and auxiliary contact configuration for your application — the 3RV2 series has a different internal trip mechanism and may not be a pin-for-pin drop-in without reviewing the wiring diagram.

Where can I buy 3RV2011-1DA15-ZX95?

This part is sourced and quoted to order against an RFQ through independent industrial automation distribution. Availability and current pricing are confirmed at quote time.

MPN
3RV2011-1DA15-ZX95