Skip to main content
Siemens 3RV2011-1DA20-ZW96 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1DA20-ZW96 SIRIUS Motor Protection Circuit B

MPN3RV2011-1DA20-ZW96
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-1DA20-ZW96, Class 10 trip, 100 kA interrupting capacity at 400 V, spring-loaded terminals, screw and snap-on 35 mm DIN rail mounting.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3RV2011-1DA20-ZW96 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00

Electrical

3RV2011-1DA20-ZW96 — Electrical
ParameterValue
Rated operational current (Ie)3.2 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)7.25 W
Power loss, per pole (AC, hot)2.4 W

Protection & Tripping

3RV2011-1DA20-ZW96 — Protection & Tripping
ParameterValue
Overload release setting range2.2 ... 3.2 A
Instantaneous short-circuit trip current42 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)100 kA
Breaking capacity at 690 V (AC)10 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V10 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes

Endurance & Switching

3RV2011-1DA20-ZW96 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0

Connections

3RV2011-1DA20-ZW96 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 2.5 mm²)

Mechanical

3RV2011-1DA20-ZW96 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany

Environmental

3RV2011-1DA20-ZW96 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m

Specifications

3RV2011-1DA20-ZW96 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

What it is and what the ratings mean

The Siemens SIRIUS 3RV2011-1DA20-ZW96 is a motor protection circuit breaker designed to protect three-phase induction motors against overload, short-circuit, and phase failure. Its Class 10 trip characteristic means it opens within 10 seconds at 7.2× the thermal setting — fast enough to protect standard IEC motors during a locked-rotor event. The interrupting capacity of 100 kA at 400 V AC means it can safely clear a bolted fault up to that level without requiring an upstream current-limiting fuse in most panel designs, simplifying coordination. Phase failure detection is built in, so a lost phase on the line side trips the breaker before single-phasing damages the motor windings.

Mounting and wiring — panel integration

Mounts via screw or snap-on onto 35 mm DIN rail per DIN EN 60715. The 45 mm width is a standard 2-module footprint — fits alongside contactors and overloads in a motor starter row without crowding. Depth of 97 mm leaves clearance for wiring ducts; the spring-loaded terminals on the main circuit accept 2× (0.5 to 4 mm²) solid or stranded conductors, so no ferrule crimping is required for the line and load connections. Mounting position is any orientation, which helps when the panel layout is tight.

Frequently asked questions

Where can I buy 3RV2011-1DA20-ZW96 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or lead-time figures are published here.

Will 3RV2011-1DA20-ZW96 drop into a panel specified for 3RV2011-0BA20?

Both are 45 mm wide and share the same DIN-rail mounting, so the footprint fits. However, the -1DA20-ZW96 carries a 100 kA interrupting rating at 400 V versus the -0BA20's lower rating — verify the panel's SCCR requirement before substitution. The -0BA20 is a different thermal setting range, so the overload protection curve will differ.

What compliance documentation does Siemens provide for this breaker?

The evidence does not list specific certifications (UL, CSA, CE, RoHS, REACH) for this order code. The SIRIUS family typically carries IEC/EN 60947-2 and -4 compliance. Request the manufacturer's declaration from your sourcing contact for the exact documentation package.

MPN