Siemens 3RV2011-1KA15-ZX95 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-1KA15-ZX95 SIRIUS Motor Protection Circuit B

MPN3RV2011-1KA15-ZX95
Active

Siemens SIRIUS 3RV2011-1KA15-ZX95 motor protection circuit breaker, Class 10, 100 kA breaking capacity at 400 V, screw and snap-on 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-1KA15-ZX95 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-1KA15-ZX95 — Electrical
ParameterValue
Rated operational current (Ie)12.5 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV2011-1KA15-ZX95 — Protection & Tripping
ParameterValue
Overload release setting range9 ... 12.5 A
Instantaneous short-circuit trip current163 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)100 kA
Breaking capacity at 500 V (AC)42 kA
Breaking capacity at 690 V (AC)6 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V4 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-1KA15-ZX95 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-1KA15-ZX95 — Connections
ParameterValue
Main-circuit terminal typescrew-type terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RV2011-1KA15-ZX95 — Mechanical
ParameterValue
Height97 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-1KA15-ZX95 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-1KA15-ZX95 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

Integrated phase failure detection trips the breaker on loss of one line — critical for preventing single-phasing damage on delta-connected motors.

The 45 mm width occupies one standard 45 mm module slot; 97 mm depth leaves clearance for wiring ducts. Mounting position any — installs horizontally or vertically without derating the trip curve. Terminals accept 2x (0.5…1.5 mm²) solid or stranded, or 2x (0.75…2.5 mm²) — sized for standard motor interposing relay wiring.

Breaking capacity by voltage

At 690 V the breaker still clears 4 kA — sufficient for most 690 V motor branch circuits in European or Canadian installations, though the 100 kA at 400 V is the headline figure for 400 V class panels. gL/gG fuse-limit ratings: 63 A at 400 V, 50 A at 500 V, 40 A at 690 V — coordinate with upstream fuse selection for full selectivity.

Frequently asked questions

What is 3RV2011-1KA15-ZX95's listed depth?

The listed depth is 97 mm.

What is 3RV2011-1KA15-ZX95's listed width?

The listed width is 45 mm, occupying one standard 45 mm DIN-rail module slot.

Will 3RV2011-1KA15-ZX95 drop into a panel specified around 3RV1011-1HA10 without rewiring?

The 3RV2011-1KA15-ZX95 shares the same 45 mm width and 35 mm DIN-rail snap-on mounting as the 3RV1011 series, so it fits the same panel footprint and DIN slot. Terminal wiring is similar — both accept 2x (0.5…1.5 mm²) or 2x (0.75…2.5 mm²) — so rewiring is not required, though verify the trip class and breaking capacity match your motor protection coordination.

MPN
3RV2011-1KA15-ZX95