Siemens 3RV2011-4AA25 — Motor Protection Circuit Breakers (MPCB)

Siemens 3RV2011-4AA25 SIRIUS Motor Protection Circuit Breake

MPN3RV2011-4AA25
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-4AA25, Class 10 trip, 30 kA breaking capacity at 400 VAC, screw and snap-on 35 mm DIN rail mount.

$45.72Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RV2011-4AA25 — Identification
ParameterValue
SeriesSIRIUS
Product designationCircuit breaker
Frame sizeS00
3RV2011-4AA25 — Electrical
ParameterValue
Rated operational current (Ie)16 A
Rated voltage20 ... 690 V
Rated voltage, AC-3 (max.)690 V
Rated frequency50 ... 60 Hz
Rated insulation voltage (Ui), pollution degree 3690 V
Rated impulse withstand voltage (Uimp)6 kV
Number of poles3
Power loss (AC, hot)9.25 W
Power loss, per pole (AC, hot)3.1 W
3RV2011-4AA25 — Protection & Tripping
ParameterValue
Overload release setting range10 ... 16 A
Instantaneous short-circuit trip current208 A
Trip classCLASS 10
Breaking capacity at 240 V (AC)100 kA
Breaking capacity at 400 V (AC)55 kA
Breaking capacity at 500 V (AC)10 kA
Breaking capacity at 690 V (AC)4 kA
Breaking capacity at 240 V100 kA
Breaking capacity at 690 V2 kA
Short-circuit trip typemagnetic
Overload release typethermal
Short-circuit protectionYes
Phase-failure detectionYes
Ground-fault detectionNo
Auxiliary switch extendableYes
3RV2011-4AA25 — Endurance & Switching
ParameterValue
Endurance, main contacts (typ.)100 000
Endurance, auxiliary contacts (typ.)100 000
Switching frequency, AC-3 (max.)15 1/h
Auxiliary CO (changeover) contacts0
3RV2011-4AA25 — Connections
ParameterValue
Main-circuit terminal typespring-loaded terminals
Main-circuit connector arrangementTop and bottom
Conductor cross-section, solid / stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded with ferrule2x (0.5 ... 1.5 mm²)
Conductor range, AWG (main contacts)2x (20 ... 12)
3RV2011-4AA25 — Mechanical
ParameterValue
Height106 mm
Width45 mm
Depth97 mm
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting positionany
3RV2011-4AA25 — Environmental
ParameterValue
Operating temperature-20 ... +60 °C
Storage temperature-50 ... +80 °C
Transport temperature-50 ... +80 °C
Relative humidity (operation)10 ... 95 %
Max. installation altitude2 000 m
3RV2011-4AA25 — Specifications
ParameterValue
Design Of The ProductFor motor protection

Product details

The 3RV2011-4AA25 carries a 30 kA rated short-circuit breaking capacity at 400 VAC. At 690 VAC the capacity drops to 2 kA, and at 240 VAC it holds 100 kA. For a 400 V panel with an available fault current under 30 kA, this breaker coordinates cleanly with a downstream contactor — no need for a separate current-limiting fuse upstream unless the SCCR exceeds that ceiling.

Width is 45 mm, depth 97 mm, height 106 mm (–). That is a single 45 mm module on the DIN rail — one standard slot. The screw terminals accept 2 × (0.5 to 2.5 mm²) solid or stranded wire. Clearance requirements: 50 mm above and below, 30 mm to the side.

Frequently asked questions

Where can I buy 3RV2011-4AA25 and what is the lead time?

The 3RV2011-4AA25 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or lead-time figures are published here.

Will 3RV2011-4AA25 drop into a panel specified around 3RV2021-4CA25 without rewiring?

The 3RV2011-4AA25 shares the same 45 mm width and DIN-rail footprint as the 3RV2021-4CA25, so it fits the same panel slot. However, the 3RV2021-4CA25 is a higher-current frame (typically 32–40 A range vs the 3RV2011's 16 A at 480/600 V), so verify the thermal setting range matches your motor FLA before swapping — the physical mount is identical, the protection range is not.

What are the key ratings for 3RV2011-4AA25?

Trip Class 10, 30 kA breaking capacity at 400 VAC, 16 A at 480 V and 600 V, phase failure detection, screw and snap-on 35 mm DIN rail mount.

MPN
3RV2011-4AA25