Skip to main content
Siemens 3VA1010-2ED32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-2ED32-0AH0 SENTRON MCCB, 100 A, 3-Pole, TM21

MPN3VA1010-2ED32-0AH0

Siemens SENTRON 3VA1010-2ED32-0AH0, 3-pole molded case circuit breaker, 100 A rated continuous current, TM210 thermal-magnetic overcurrent release, 32 kA breaking capacity at 415 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1010-2ED32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1010-2ED32-0AH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1010-2ED32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1010-2ED32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1010-2ED32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1010-2ED32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1010-2ED32-0AH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Line protection MCCB — 100 A, 3-pole, TM210 release

The Siemens SENTRON 3VA1010-2ED32-0AH0 is a 3-pole molded case circuit breaker rated for 100 A continuous current at 40 °C, with a TM210 thermal-magnetic overcurrent release. Breaking capacity is 32 kA at 415 V AC, which drops to 13.6 kA at 440 V and 7.5 kA at 690 V — the 415 V figure is the one that governs for most European 400 V distribution panels. At 240 V it interrupts 52.5 kA, so it handles high-fault points near the transformer secondary without issue. That keeps the part simple and reliable for basic feeder or branch protection where you don't need selectivity curves or remote trip signalling. Operating temperature range is -25 °C to 70 °C, with a slight derating curve above 55 °C — at 65 °C it still carries 92 A, at 70 °C it's 90 A.

Width is 76.2 mm, depth 70 mm, height 130 mm. The 70 mm depth leaves clearance for rear busbar connections in a shallow enclosure. Terminal design accepts copper or aluminium conductors; torque ratings follow the Siemens installation manual.

Thermal derating note

At 55 °C it derates to 96 A, at 60 °C to 94 A, at 65 °C to 92 A, at 70 °C to 90 A. The mechanical endurance is 15,000 operations — that's the latching cycle count, not the electrical switching life under load.

Frequently asked questions

How do I get current pricing and availability for 3VA1010-2ED32-0AH0?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through independent distribution channels.

What is the breaking capacity of 3VA1010-2ED32-0AH0 at 415 V?

32 kA at 415 V AC. At 240 V it interrupts 52.5 kA; at 440 V it drops to 13.6 kA; at 690 V it is 7.5 kA.

What auxiliary contacts does this MCCB come with?

It is fitted with 2 auxiliary switches plus 1 trip alarm switch (HQ designation).

What is the difference between 3VA1010-2ED32-0AH0 and 3VA1010-2ED32-0JA0?

The -0JA0 variant carries a different auxiliary contact configuration. The -0AH0 has 2 aux + 1 trip alarm switch; the -0JA0 has a different auxiliary contact version. Both share the same frame, 100 A rating, TM210 release, and breaking capacity — they drop into the same panel footprint and buswork, but the auxiliary wiring differs.

MPN
3VA1010-2ED32-0AH0