Siemens 3VA1050-4ED42-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1050-4ED42-0BC0 SENTRON MCCB, 50 A, 4-Pole, 121 k

MPN3VA1050-4ED42-0BC0

Siemens SENTRON 3VA1050-4ED42-0BC0, molded case circuit breaker, 4-pole, 50 A rated current, 121 kA breaking capacity at 240 V, TM210 overcurrent release, undervoltage release.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1050-4ED42-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1050-4ED42-0BC0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C48 A
Current at 60 °C47 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA
3VA1050-4ED42-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1050-4ED42-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1050-4ED42-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1050-4ED42-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1050-4ED42-0BC0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm

Product details

Line Protection MCCB with Undervoltage Release

The 121 kA breaking capacity at 240 V gives headroom for high-fault installations; at 415 V it still interrupts 75.6 kA, and at 690 V it holds 11.9 kA.

The 50 A rating holds flat from 40 °C to 50 °C ambient, then derates to 48 A at 55 °C, 47 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C. In a sealed panel with multiple breakers ganged, the 70 °C derating figure (45 A) is the realistic continuous limit — plan for that if the enclosure runs hot. Dimensions are 70 mm deep, 101.6 mm wide, and 130 mm high — a standard 4-pole MCCB footprint for DIN-rail or screw-mount panel integration.

Frequently asked questions

What is the breaking capacity of 3VA1050-4ED42-0BC0 at different voltages?

At 240 V it interrupts 121 kA, at 415 V it handles 75.6 kA, at 440 V it breaks 52.5 kA, and at 690 V it interrupts 11.9 kA.

What overcurrent release does 3VA1050-4ED42-0BC0 use?

It uses a TM210 thermal-magnetic overcurrent release — fixed curve, no electronic adjustment, suited for standard line-feeder protection.

Where can I buy 3VA1050-4ED42-0BC0 and how is it quoted?

This MCCB is sourced to order through independent distribution. Submit an RFQ for current pricing and availability confirmation.

Does 3VA1050-4ED42-0BC0 include an undervoltage release?

Yes, it ships with an integrated undervoltage release (UVR) that trips the breaker on loss of control voltage.

MPN
3VA1050-4ED42-0BC0