Skip to main content
Siemens 3VA2140-0HN46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-0HN46-0AA0 SENTRON MCCB, 40 A, 4-Pole, ETU35

MPN3VA2140-0HN46-0AA0
Active

Siemens SENTRON 3VA2140-0HN46-0AA0, molded case circuit breaker, 4-pole, 40 A continuous, ETU350 electronic trip unit, 440 kA at 415 V AC, 690 V AC rated voltage.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2140-0HN46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2140-0HN46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.1.2 W
3VA2140-0HN46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2140-0HN46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2140-0HN46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2140-0HN46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2140-0HN46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

SENTRON 3VA2 MCCB with ETU350 Trip Unit

The 690 V AC rated operating voltage and 800 V rated insulation voltage confirm suitability for 400 V line-to-line systems with margin for transient overvoltages.

Selectivity and Coordination

The 4-pole construction with adjustable N-conductor protection (OFF or 100% setting) allows the breaker to serve both 3-phase + N systems and full 4-pole isolation where the neutral must be switched. The ETU350 trip unit provides electronic overload and short-circuit protection with adjustable I²t curves — essential for selective coordination with downstream branch breakers. At 40 A continuous the breaker covers feeder and large motor circuits; the 60 A minimum adjustment range and 480 A maximum frame indicate the same physical frame accommodates higher-rated trip units if the load grows.

Installation and Environmental Limits

Dimensions of 86 mm depth × 140 mm width × 181 mm height fit standard SENTRON 3VA2 panel cutouts and busbar systems. Storage limits of -40 °C to 80 °C cover cold warehouses and shipping.

Frequently asked questions

What are the key ratings of this MCCB?

The 3VA2140-0HN46-0AA0 is rated 40 A continuous with a 440 kA breaking capacity at 415 V AC, 690 V AC rated operating voltage, and an 800 V rated insulation voltage. It uses the ETU350 electronic trip unit in a 4-pole configuration.

Where can I buy 3VA2140-0HN46-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Submit an RFQ for current pricing and availability confirmation.

What compliance documentation is available for this breaker?

As a current-production Siemens SENTRON product, the 3VA2140-0HN46-0AA0 carries the manufacturer's standard declarations of conformity for IEC/EN 60947-2, RoHS, and REACH. Specific certification documents are provided with the shipment or available on request.

MPN
3VA2140-0HN46-0AA0