Siemens 3VA2140-5JP32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-5JP32-0AA0 SENTRON MCCB, 40 A, 3-Pole, ETU55

MPN3VA2140-5JP32-0AA0
Active

Siemens SENTRON 3VA2140-5JP32-0AA0, molded case circuit breaker, 3-pole, 40 A, ETU550 electronic trip unit, 187 kA at 240 V, line protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2140-5JP32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2140-5JP32-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.1.6 W
3VA2140-5JP32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
3VA2140-5JP32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2140-5JP32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2140-5JP32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2140-5JP32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2140-5JP32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current Iu of 40 A across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. The ETU550 electronic trip unit manages overload and short-circuit curves, and the breaker communicates via an integrated communication function, so it reports status and trip events back to a PLC or BMS without an add-on module.

At 415 V and 440 V the breaker still clears 121 kA — that covers most industrial distribution panels fed from a 500 kVA to 2 MVA transformer where the prospective fault current at the main switchboard lands in the 50–100 kA range. At 500 V it drops to 75.6 kA, and at 690 V it falls to 3.7 kA, so for 690 V drives or mining gear the breaker is only suitable downstream of a current-limiting device.

The front protection is IP40.