Skip to main content
Siemens 5SL4625-6 — 4-Pole MCB (DIN Rail)

Siemens 5SL4625-6 SENTRON MCB, 25A B-Curve 3P+N 10kA

MPN5SL4625-6
Active

Siemens SENTRON 5SL4625-6 miniature circuit breaker, 25 A, B-curve, 3P+N, 400 V AC, 10 kA breaking capacity per EN 60898 / IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4625-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4625-6 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SL4625-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL4625-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL4625-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL4625-6 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)3 W

Product details

The Siemens 5SL4625-6 is a SENTRON miniature circuit breaker rated 25 A with a B-curve tripping characteristic, 3P+N poles, and a 10 kA breaking capacity at 400 V AC per both EN 60898 and IEC 60947-2. That 10 kA rating means it safely interrupts fault currents up to that level without upstream cascading — standard for residential and light commercial distribution boards. The B-curve trips between 3 and 5 times rated current, so it's sized for resistive and general-purpose loads where you want fast clearing on moderate overloads, not the inrush tolerance of a C-curve.

Panel fit and wiring

Snap-on DIN rail mount, any position. At 72 mm wide (4 modular width units), it occupies four standard 18 mm slots in the distribution board. Depth is 76 mm, installation depth 70 mm — verify gland plate clearance if retrofitting into a shallow enclosure. IP20 with connected conductors; pollution degree 2 and overvoltage category III, which covers fixed-installation downstream of the main distribution. Sealable, halogen-free, silicon-free — relevant for clean-room or sensitive-environment builds where outgassing matters.

Frequently asked questions

Where can I buy 5SL4625-6 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is the breaking capacity of 5SL4625-6?

10 kA at 400 V AC per both EN 60898 and IEC 60947-2, which covers standard residential and commercial fault levels.

MPN
5SL4625-6