Siemens 5SU9336-1CN20 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9336-1CN20 SENTRON RCBO, 20A, 30mA, Type C, 6kA

MPN5SU9336-1CN20

Siemens SENTRON 5SU9336-1CN20, 3-pole RCBO, 20 A rated at 30 °C, 30 mA residual current, Type C tripping characteristic, 6 kA breaking capacity per EN 60898.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SU9336-1CN20 — Electrical Ratings
ParameterValue
Number of poles3
Overvoltage categoryIII
5SU9336-1CN20 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9336-1CN20 — Mechanical
ParameterValue
Mounting positionany
Width in modular units6
Maximum75 °C
Minimum-40 °C
Width108 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9336-1CN20 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9336-1CN20 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9336-1CN20 is a 3-pole SENTRON RCBO (residual current operated circuit breaker with overcurrent protection) rated 20 A at 30 °C with a 30 mA residual current trip and Type C tripping characteristic.

The 30 mA residual current trip protects against direct-contact earth faults — the standard for socket-outlet circuits in most IEC-based installations.

Thermal derating in the panel

At 40 °C it derates to 18.6 A, at 50 °C to 17.2 A, and at 55 °C to 16.6 A. If this RCBO sits in a crowded enclosure near other heat sources, size the load to the derated figure — the 75 °C maximum operating temperature is the internal limit, not a free pass to run full current in a hot panel. The unit occupies 6 modular width units (108 mm) on the DIN rail; depth is 77 mm with 70 mm installation depth. Mounting position is unrestricted.

Compliance and approvals

It carries IP20 protection (finger-safe) once installed in a distribution board with conductors connected. The overvoltage category is III, pollution degree 2 — standard for fixed-installation switchgear. Supply can enter from top or bottom, simplifying panel layout.

Frequently asked questions

Where can I buy 5SU9336-1CN20 and get current pricing?

We source and quote this part to order against an RFQ. Availability and current pricing are confirmed at quote time through our independent distribution channels.

What is the difference between 5SU9336-1CN20 and 5SY6020-7?

The 5SY6020-7 is a Siemens miniature circuit breaker (MCB) only — it provides overcurrent protection but no residual current protection. The 5SU9336-1CN20 combines both functions in one unit (RCBO). They are not drop-in interchangeable; an RCBO replaces an MCB only if the wiring and panel space accommodate the additional neutral connection and the 6-module width.

What are the key ratings of 5SU9336-1CN20?

3-pole RCBO, 20 A rated at 30 °C, 30 mA residual current, Type C characteristic, 6 kA breaking capacity per EN 60898 and IEC 60947-2, 440 V insulation voltage.

What is the physical size of 5SU9336-1CN20?

Width 108 mm (6 modular units), depth 77 mm, height 90 mm, with 70 mm installation depth.