Siemens 5SY4306-7KK11 — 3-Pole MCB (DIN Rail)

Siemens 5SY4306-7KK11 SENTRON MCB, 3P C-Curve 6A, 10kA/35kA

MPN5SY4306-7KK11

Siemens SENTRON 5SY4306-7KK11, 3-pole miniature circuit breaker, C tripping characteristic, 6 A rated current, 10 kA (EN 60898) / 35 kA (IEC 60947-2) breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4306-7KK11 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Suitability for operationMechanical engineering / industry
5SY4306-7KK11 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-235 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree3
5SY4306-7KK11 — Electrical
ParameterValue
Rated current (AC)6 A
Rated voltage (AC, multi-phase)440 V
5SY4306-7KK11 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
5SY4306-7KK11 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

The Siemens 5SY4306-7KK11 is a 3-pole miniature circuit breaker from the SENTRON series, designed for AC circuits with a C tripping characteristic and a rated current of 6 A at 35 °C. The 10 kA breaking capacity per EN 60898 covers standard domestic and light commercial fault levels; the 35 kA rating per IEC 60947-2 is what matters for industrial panel coordination, where upstream fault currents can be higher.

Derating and thermal reality

At 40 °C ambient the breaker must be derated to 5.71 A, at 50 °C to 5.41 A, and at 60 °C to 5.09 A. If the panel ambient runs at 50 °C, a 6 A circuit is effectively a 5.4 A device — plan the load accordingly. The breaker is rated for any mounting position and any supply cord entry position, which simplifies panel layout. It occupies 3 modular width units (54 mm) on the DIN rail, with a depth of 76 mm and an installation depth of 70 mm. The quick assembly fastening system means it snaps onto the rail without tools.

Frequently asked questions

What is the breaking capacity of 5SY4306-7KK11?

10 kA per EN 60898 for standard domestic/commercial duty, and 35 kA per IEC 60947-2 for industrial panel coordination. The higher figure governs when the breaker is used in a distribution board with high prospective fault current.

Will 5SY4306-7KK11 drop into a panel specified around 5SY4140-7?

Both are 3-pole SENTRON MCBs on the same DIN-rail footprint (3 modular width units, 54 mm). The 5SY4140-7 is a higher-current variant (40 A vs 6 A). The physical fit is identical — same width, same rail clip, same terminal layout — so no rewiring is needed for the mounting. The breaker's rating must match the circuit protection requirement.

Where can I buy 5SY4306-7KK11 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial response.