Siemens 5SY4632-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY4632-7 SENTRON MCB, 4P C-Curve, 10kA IEC/EN 60898

MPN5SY4632-7
Active

Siemens SENTRON 5SY4632-7 miniature circuit breaker, 4-pole (3P+N), C-curve, 10 kA per IEC/EN 60898-1, 20 kA per IEC 60947-2, 72 mm wide, IP20.

$58.42Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4632-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4632-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SY4632-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY4632-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4632-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4632-7 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)2.6 W

Product details

The Siemens SENTRON 5SY4632-7 is a 4-pole miniature circuit breaker (3P+N) with a C tripping characteristic, designed for final-distribution and industrial control panels per IEC/EN 60898-1 and IEC 60947-2 / UL1077. Rated breaking capacity is 10 kA under IEC/EN 60898-1 and 20 kA under IEC 60947-2; at DC (per IEC 60947-2) it handles 15 kA up to 72 V. That dual rating means it qualifies for both residential and industrial coordination studies.

Mounting position is any orientation; IP20 with conductors connected, so it lives inside a panel enclosure. Neutral conductor is switched (4-pole), so it disconnects the neutral alongside the phases — required in TN-S or TT systems where neutral isolation matters. Installation depth is 70 mm (device depth 76 mm). Halogen-free and silicon-free construction, sealable for lockout/tagout.

Humidity derating applies above 55 °C: max 95% RH at 55 °C, tapering to 35% at 75 °C. Energy limitation class 3 means fast arc extinction, limiting let-through energy to downstream equipment.