Siemens 5SY4663-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY4663-7 SENTRON MCB, 4P C-curve, 10kA IEC

MPN5SY4663-7
Active

Siemens SENTRON, miniature circuit breaker, 5SY4663-7, 4-pole (3P+N), C characteristic, 10 kA (EN 60898-1) / 15 kA (IEC 60947-2), 400 V AC, 60 V DC.

$101.60Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4663-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4663-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SY4663-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY4663-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4663-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4663-7 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)6 W

Product details

It protects final circuits in commercial and industrial panels against overload and short-circuit, rated to break 10 kA per IEC/EN 60898-1 and 15 kA per IEC 60947-2 at 400 V AC. The C curve (5–10× In) handles moderate inrush loads like motor starters and small transformers without nuisance tripping, while the dual standard means it qualifies for both distribution-board (60898-1) and industrial-installation (60947-2) applications.

Under UL 1077 and CSA C22.2 No. 235 the rating is 5 kA, so for North American supplementary-protection applications the available fault current must stay at or below that level. The 4-module-width body (72 mm wide, 90 mm tall, 76 mm deep, 70 mm installation depth) fits standard 18 mm/module DIN-rail enclosures.

The breaker carries IEC/EN 60898-1 and IEC/EN 60947-2 certification for Europe, plus UL 1077 and CSA C22.2 No. 235 for North American supplementary protection. The manufacturer provides RoHS and REACH declarations with the standard documentation package.

Frequently asked questions

Where can I buy 5SY4663-7 and get a price?

It is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance documentation does Siemens provide for 5SY4663-7?

The breaker is certified to IEC/EN 60898-1, IEC/EN 60947-2, UL 1077, and CSA C22.2 No. 235. It is halogen-free and silicon-free. RoHS and REACH declarations are part of the standard documentation package.

What are the key ratings of 5SY4663-7?

4-pole (3P+N), C characteristic, 10 kA per EN 60898-1, 15 kA per IEC 60947-2, 5 kA per UL 1077, rated 400 V AC / 60 V DC. Dimensions: 72 mm wide × 90 mm tall × 76 mm deep, 70 mm installation depth.

MPN
5SY4663-7