Skip to main content
Siemens 5SY4663-8 — 4-Pole MCB (DIN Rail)

Siemens 5SY4663-8 SENTRON MCB, D-curve, 3P+N, 10kA / 15kA, 4

MPN5SY4663-8
Active

Siemens SENTRON 5SY4663-8, 4-pole miniature circuit breaker, D tripping characteristic, 3P+N, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 400 V AC, 4 MW width.

$142.24Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4663-8 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4663-8 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SY4663-8 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY4663-8 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4663-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4663-8 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)5 W

Product details

That matters when you need full isolation on a TN-S or TT system or when downstream equipment expects a broken neutral during a fault. D-curve tripping characteristic means it holds through the high inrush of motor loads, transformers, or welding gear — magnetic trip kicks in at 10–20× rated current rather than the 5–10× of a C-curve. If you're specifying for a control panel feeding contactors or small drives, D-curve avoids nuisance trips on startup. Breaking capacity sits at 10 kA per EN 60898 and 15 kA per IEC 60947-2 — the higher figure is the one that governs in industrial panels where the prospective fault current can exceed 10 kA.

Standards and compliance — what the approvals cover

Rated and certified to IEC / EN 60898-1 (domestic-style MCB) and IEC / EN 60947-2 / UL1077 (industrial MCB / supplementary protector). The dual rating gives you flexibility: the 10 kA figure is the standard household breaking capacity, while the 15 kA per 60947-2 covers the higher fault levels typical in factory distribution boards. UL1077 listing is for supplementary protection — not a branch-circuit rated breaker, so check your local code if the panel requires a UL489 device. Halogen-free and silicon-free construction — relevant if the panel goes into a clean room, semiconductor fab, or food-processing area where outgassing from a fault could contaminate the environment. Degree of pollution 3 and overvoltage category III confirm it's rated for the conductive, transient-heavy environment inside an industrial enclosure.

Physical fit — panel integration notes

Occupies 4 modular width units (4 MW) on a DIN rail — 72 mm wide, 90 mm tall, 76 mm deep. The 70 mm installation depth is the key clearance number for the enclosure depth behind the panel door. Mounts in any position and uses the Siemens quick-assembly system — clips onto the rail without tools and locks with the integral latch. Combined terminal at both top and bottom — the same terminal accepts both the busbar fork and the stranded/solid wire, so you don't need separate ring-lug adapters. IP20 with connected conductors is the norm for a panel-mount breaker; keep the front cover on during live work. Sealable — the toggle can be locked in the off position with a padlock hasp, which satisfies lockout/tagout requirements without an external breaker lock. Handy for a quick maintenance isolation on a machine panel.

Environmental and application range

Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz and 50 m/s² at 25–150 Hz. That's enough for installation on a machine frame or near a motor — not a problem in a standard cabinet, but worth noting if the breaker mounts on a vibrating conveyor line. Supply frequency is 50/60 Hz — universal for worldwide use. Operating voltage peak is 440 V AC for both single-phase and multi-phase operation, so it covers 400 V nominal systems with tolerance.

Frequently asked questions

What is the breaking capacity of 5SY4663-8?

10 kA per EN 60898 and 15 kA per IEC 60947-2. At 400 V AC the higher figure governs for industrial panel fault levels.

Will 5SY4663-8 drop into a panel specified around 5SY6332-7CC without rewiring?

Not without checking the existing busbar and wiring layout. Both are 4-pole SENTRON MCBs on DIN rail, but the 5SY4663-8 is a 3P+N unit with switched neutral, while the 5SY6332-7CC may have a different pole configuration or terminal layout. Compare the wiring diagram before swapping.

What compliance documentation does Siemens provide for 5SY4663-8?

The breaker is certified to IEC / EN 60898-1, IEC / EN 60947-2, and UL1077. It is halogen-free and silicon-free. Standard Siemens declarations for RoHS and REACH are available on request.

Where can I buy 5SY4663-8 and what is the lead time?

The 5SY4663-8 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no blanket stock figure.

MPN
5SY4663-8